HomeMy WebLinkAboutOrdinance 17-014 Amending Planned Development District PD-19 to build two additions to the existing school and siteORDINANCE NO. 17-014
AN ORDINANCE OF THE CITY OF UNIVERSITY PARK, TEXAS, AMENDING
THE COMPREHENSIVE ZONING ORDINANCE AND MAP, AS HERETOFORE
AMENDED, BY AMENDING PLANNED DEVELOPMENT DISTRICT NO. 19 FOR THE
PROPERTY DESCRIDED AS LOTS 1-28, BLOCK E, UNIVERSITY ANNEX ADDITION
TO THE CITY OF UNIVERSITY PARK, DALLAS COUNTY, TEXAS, BEING
COMMONLY KNOWN AS 3555 GRANADA; APPROVING AN AMENDED DETAILED
SITE PLAN; PROVIDING SPECIAL CONDITIONS; PROVIDING FOR THE REPEAL OF
ALL ORDINANCES IN CONFLICT; PROVIDING A SEVERABILITY CLAUSE;
PROVIDING FOR A PENALTY OF FINE NOT TO EXCEED THE SUM OF TWO
THOUSAND DOLLARS ($2,000.00) FOR EACH OFFENSE; AND PROVIDING AN
EFFECTIVE DATE.
WHEREAS, the Planning and Zoning Commission of the City of University Park and the
City Council ofthe City of University Park, in compliance with the laws ofthe State ofTexas with
reference to the granting of zoning classifications and changes, have given the requisite notices by
publication and otherwise, and have held due hearings and afforded a full and fair hearing to all
property owners generally and to all persons interested and situated in the affected area and in the
vicinity thereof, and the City Council of the City of University Park is of the opinion and finds that
said zoning change should be granted and that the Comprehensive Zoning Ordinance and Map should
be amended; NOW, THEREFORE,
BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF UNIVERSITY
PARK, TEXAS:
SECTION 1. That the Comprehensive Zoning Ordinance and Map are amended by
amending Planned Development District No. 19 ("PD-19"), for the property described as Lots 1-28,
Block E, University Annex Addition to the City of University Park, Dallas County, Texas, commonly
known as 3555 Granada Avenue, the Hi ghland Park Middle School and the McCulloch Intermediate
School (the "site"), and approving an amended detailed site plan (the "plan "), subject to additional
special conditions, for addition of a three story classroom building on the northeast corner ofthe site
(Building No. 3), relocation of the tennis court, reconfiguration of parking spaces, and interior
renovations. This amendment affects only the portion of the site in the City; the balance of the site is
in the Town of Highland Park and the plan will be considered by the Highland Park Town Council in
the manner provided by law.
SECTION 2. That the amended detailed site plan for PO No. 19, attached hereto,
collectively, as Exhibit "A" and made part hereof for all purposes, is hereby approved as the detailed
site plan for said Planned Development District 19, as required by Section 17-10 I (2) of the
Comprehensive Zoning Ordinance of the City of University Park, Texas. That the Planning and
Zoning Commission has reviewed the plan and unanimously recommended its approval.
SECTION 3. That the amendment of the plan for PD-19 is subject to the following
additional special conditions:
a. All pennanent improvements in thi s PD-19 will be constructed or placed and maintained in
accordance with the plan;
b. HPISD will provide adequate security lighting during construction of the additions shown
on the plan approved hereby;
c. The construction site will be screened with a 72" screening fence of dark green or black
windscreen fabric installed on a chain link frame or of other materials approved by the
Director of Community Development; all trash receptacles will be placed within the
screened area;
d. Construction activities on the site will be conducted Monday through Saturday from 7:00
a.m. to 6:00p.m., unless special permission is granted by the Director of Public Works;
e. Background checks will be conducted by the District's contractors for all employees on the
site prior to their working on the project, and the results of the checks provided to the
District, which will retain a file of such checks; no convicted felon or pedophile will be
permitted to work on the project site;
f. That Building No.3 shall be set back a distance of38.96' from Granada and 107.28 ' from
Key Street. Building No.3 shall not exceed 48.8' in height;
g. The District shall provide 64 off-street parking spaces, plus 6 handicap spaces (including
I van accessible space) above ground, and shall provide 177 parking spaces, plus 6
handicap spaces (including I van accessible space) below ground for the site;
h. Permitted temporary uses shall include: construction management and contract
administration trailer and offices; construction equipment and/or materials,
containers/trailers/buildings; construction materials staging/lay-down/storage areas.
Any portion of the site to be used for the temporary construction uses shall be paved
with an all-weather surface (minimum 2" minus/#4 crushed stone. These temporary
uses will be permitted for 30 months from the effective date of this ordinance;
1. A full-time point of contact will be provided by HPISD to answer questions and
complaints during construction;
J. All construction vehicles shall be required to park on-site during construction;
k. A full-time point of contact will be provided by HPISD to answer questions and
complaints during construction;
I. The issuance of a building permit is subject t review and approval of building plans for
compliance with applicable city codes and ordinances; and,
m. Except as amended hereby, the special conditions ofthe ordinance creating, and those
of any ordinance amending, PO 19 shall remain in full force and effect.
SECTION 4. All ordinances of the City of University Park in conflict with the provisions of
this ordinance are hereby repealed.
SECTION 5. Should any sentence, paragraph, subdivision, clause, phrase or section ofthis
ordinance be adjudged or held to be unconstitutional, illegal or invalid, the same shall not affect the
validity of this ordinance or any part or provision thereof, other than the part so declared to be invalid,
illegal or unconstitutional, and shall not affect the validity ofthe Comprehensive Zoning Ordinance
and Map.
SECTION 6. Any person , firm or corporation violating any of the provisions of this
ordinance or the Comprehensive Zoning Ordinance, as amended hereby, shall be deemed guilty of a
misdemeanor and, upon conviction in the municipal court of the City of University Park, Texas, shall
be punished by a fine not to exceed the sum of two thousand dollars ($2,000.00) for each offense, and
each day any such violation shall continue shall be deemed to constitute a separate offense.
SECTION 7. This ordinance shall take effect immediately from and after its passage and the
publication ofthe caption, as the law and Charter in such cases provide.
DULY PASSED by the City Council of the City of University Park, Texas, on the 16th
day of May 2017.
PPROVEDA~~
CITY ATTORNEY
(RLD/05 /11 /17; 86209)
APPROVED:
OLIN B. LANE, MAYOR
ATTEST:
CHRISTINE GREEN, CITY SECRETARY
ORIGINAL SHEET - ARCH E1 (30"x42")
Stantec Project #:
Drawing No.
Project No.
Title
Revision
Scale
Revision By Appd YYYY.MM.DD
By Appd YYYY.MM.DDIssued
The Contractor shall verify and be responsible for all dimensions. DO
NOT scale the drawing - any errors or omissions shall be reported to
Stantec without delay.
The Copyrights to all designs and drawings are the property of
Stantec. Reproduction or use for any purpose other than that
authorized by Stantec is forbidden.
Copyright Reserved
Tel:
Fax:
www.stantec.com
PRELIMINARY
NOT FOR CONSTRUCTION
Not for permits, pricing or other official purposes.
This document has not been completed or checked and is
for general information or comment only.
Seal Block
3/9/2017 2:01:54 PM RevitServer:\\000000000\ENTER_PATH
MIS / HPMS Additions and Renovations
3555 Granada Ave, Dallas TX 75205
PD RE-SUBMITTAL 2017.03.10
214000466
COVER
PD000R
214000466
Author Approver
Stantec Architecture Inc.
5717 Legacy Drive Suite 250
Plano, TX 75024-4246
(214) 473-2400
(214) 473-2401
100% DESIGN DEVELOPMENT 2017.01.27
DRAWING INDEX - PD DOCS
NO.DRAWING NAME
CIVIL
C0.10R SITE PLAN
LANDSCAPE
LP101R OVERALL LANDSCAPE PLAN
LP102R LANDSCAPE PLAN AREA A
LP103R LANDSCAPE PLAN AREA B
ARCHITECTURE
PD000R COVER
PD011R ARCHITECTURAL SITE PLAN
PD111R OVERALL FIRST FLOOR PLAN & UNDERGROUND PARKING GARAGE
PD121R SECOND LEVEL FLOOR PLAN
PD131R THIRD LEVEL FLOOR PLAN
PD200R RENDERINGS
PD201R EXTERIOR ELEVATIONS
PD210R STREET VIEWS SHOWING RTUS
EXHIBIT A
12345678ABCDEFClient/ProjectDrawing No.Project No.TitleORIGINAL SHEET - ARCH E1 (30"x42")Permit-SealRevisionScalePRELIMINARYNOT FOR CONSTRUCTIONNot for permits, pricing or other official purposes.This document has not been completed or checked and isfor general information or comment only.1/26/2017 3:11:30 PMC:\Users\Public\Documents\Local_Revit_Files\214000466-MISHPMS-A16_jcastellanos.rvt
MIS / HPMS Additions and RenovationsHighland Park ISD2140004663555 Granada Ave, Dallas TX 75205RevisionByAppdYYYY.MM.DDByAppdYYYY.MM.DDIssued100% CONTRACT DOCUMENTSAuthorApprover2017.04.12ABCDEFGHJKLThe Contractor shall verify and be responsible for all dimensions. DONOT scale the drawing - any errors or omissions shall be reported toStantec without delay.The Copyrights to all designs and drawings are the property ofStantec. Reproduction or use for any purpose other than thatauthorized by Stantec is forbidden.Copyright ReservedConsultant TypeConsultantsKey PlanConsultant Namewww.stantec.comStantec Architecture Inc.5717 Legacy Drive Suite 250Plano, TX 75024-4246Tel: (214) 473-2400 / Fax: (214) 473-2401C0.101"=40'SITE PLANC0.10
PRELIMINARY
PRELIMINARY
PRELIMINARY
12' CHAIN-LINKFENCE
CHAIN-LINKFENCE
31.3
TOWN OF HIGHLAND PARKCITY OF UNIVERSITY PARK
CITY OF UNIVERSITY PARK
TOWN OF HIGHLAND PARK
XXX.XXFL
XXX.XXFL 16.1'6.5'1.42'
BRICKWALL
1.08'BRICKWALL
BRICKWALL
BRICKWALL
CROSSWA LK
CROSSWALK 21 SPACES46 SPACES 3 SPACES16 SPACES16 SPACES10 SPACES1 SPACE1 SPACE2 SPACESBRICKSIGN
RD
RD
PLAQUE PLAQUE
GP GP
FP
PLAQUE
GPGPGP
FH
CO
CO
CO CO
CO
CO
555.73TOP
558.79TOP
561.24TOP
552.76TOP
552.16TOP
556.42TOP
561.66TOP
557.08TOP
COOLINGTOWER
10' INLET
10' INLET10'INLET
10'INLET546.56FL
4'INLET&549.44
4'INLET&549.12
5' INLET
UGP
TRANS-FORMERPAD
S S
10" OAK
S
6" OAK
S
10" OAK
S
10" PECAN
12" PECAN
WV
FH
S
S
29" OAK29" OAK4" OAK
S
WD
GRANADA AVENUE
HIGH SCHOOL AVENUENORMANDY AVENUE KEY STREETBINKLEY AVENUE
STINSON FIELD
NEW TENNIS COURTS
NEW HARD
SURFACE
PLAY
200
UNDERGROUND
PARKING SPOTS
NEW GARAGE
ENTRY/EXIT
DRIVE
EXITBLDG # 3
ADDITION
BLDG # 4 ADDITION
EXISTING BUILDING
SHOT PUTHIGH
JUMP
POLE VAULTGARAGE
STAIR EXIT
RUNNING TRACK
RUNNING TRACK
18 183 10
ENTRYLONG JUMPUNDERGROUND
TUNNEL TO
BUILDING
NEW SIDEWALK
NEW SIDEWALK
NEW
SIDEWALK
NEW SIDEWALK
NEW
SIDEWALK
EXISTING
SOD
STREET VIEW ACROSS
SIDEWALK - F4/PD210
STREET VIEW ACROSS
SIDEWALK - F1/PD210
STREET VIEW ACROSSSIDEWALK - D4/PD210STREET VIEW ACROSSSIDEWALK- D1/PD210STREET VIEW ACROSSSIDEWALK - B1/PD210STREET VIEW ACROSS
SIDEWALK - B4/PD210
NO COURT LIGHTING
TO BE PROVIDED
CAMERA LOCATION -
5'-6" A.F.F.
CAMERA LOCATION
- 5'-6" A.F.F.
CAMERA LOCATION
- 5'-6" A.F.F.
CAMERA LOCATION -
5'-6" A.F.F.
CAMERA LOCATION -
5'-6" A.F.F.
CAMERA LOCATION
- 5'-6" A.F.F.
RENDERING VIEW -
C2/PD200
RENDERING VIEW -
F2/PD200
1 2 3 4 5 6 7 8
A
B
C
D
E
F
The Contractor shall verify and be responsible for all dimensions. DO
NOT scale the drawing - any errors or omissions shall be reported to
Stantec without delay.
The Copyrights to all designs and drawings are the property of
Stantec. Reproduction or use for any purpose other than that
authorized by Stantec is forbidden.
Copyright Reserved
Client/Project
Drawing No.
Project No.
Title
ORIGINAL SHEET - ARCH E1 (30"x42")
Permit-Seal
Revision
Revision
Scale
Consultant Type
By Appd YYYY.MM.DD
By Appd YYYY.MM.DDIssued
PRELIMINARY
NOT FOR CONSTRUCTION
Not for permits, pricing or other official purposes.
This document has not been completed or checked and is
for general information or comment only.
Consultants
Key Plan
Notes
Consultant Name
www.stantec.com
3/9/2017 2:35:15 PMC:\Users\Public\Documents\Local_Revit_Files\214000466-MISHPMS-A16_ddain.rvt 1" = 50'-0"
MIS / HPMS Additions and Renovations
Highland Park ISD
ARCHITECTURAL SITE PLAN
PD011R
214000466
3555 Granada Ave, Dallas TX 75205
PD RE-SUBMITTAL JC BH 2017.03.10
Stantec Architecture Inc.
5717 Legacy Drive Suite 250
Plano, TX 75024-4246
Tel: (214) 473-2400 / Fax: (214) 473-2401
1" = 50'-0"PD011R
F2 ARCHITECTURAL SITE PLAN
DN
UP
DNDN
UP
C1
A201
B3A201E4
A201E1A201 F7A201B1
A201
C6
A201
F1A201F5A201GIRLS
LAB
BOYS
WK/COPY
IDF
CLRM
CLRM
CLRM
WRKRMLAB PREP
STORAGE
STORAGE
LARGE ASSEMBLY
ELEC
TLT
VEST
ELEV 1
STAIR 1
CORR
FLEX SPACE
SPED REC.
SPED CR SPED CRSTAFF CONF/MTG
TLT
CORR
SPED WRST
SPED CRSPED CR
CPY WRKRM
TLT
CORRARD MTG/CONF
TEST/ASSMT
TEST/ASSMT
ELEC
S THRPY/SLP OFF
S THRPY/SLP OFF
S THRPY/SLP OFF
ED DIAG OFF
LSSP OFF
LSSP OFF
CORRIDOR
CORRIDOR
CORRIDOR
SPED OFF
ARD MTG/CONF
CONF.CNSLR OFF CNSLR OFF CNSLR OFFCNSLR OFF CNSLR OFF
CORR
SPED OFF
TLT
TLT
CONF.STRG
CONF.
ISS
FILES/RECORDS
STORAGECOPY/WORK RM
ASSEM/TEST
CLST
SUPPORT STAFF
LIFE SKILLSM/SENS. SKILLS
CORRIDOR
TEACHER'S LOUNGE
VAULT/SAFE
BOOKKEEPER
TREATMENT
TLT STRG
SICK RM
NURSNG WRKST
CLINIC RECP
JAN
TLT
M/ GROUP ENS.
STO.
STO.
BOYS
GIRLS
ELEV 2
CLRM
CLRM
WRK
LAB
CLRM
STAIR 9
FLEX SPACE
LAB PREP
STAIR 8
VEST
CORRIDOR
SHOWERS
BOYS LOCKER RM
WEIGHT RM
BOYS LOCKER RM
CLASSROOM
GIRLS LOCKER RM
S/GR.S/GR. S/GR.
OFFICE
OFFICE
M/ ENS.
S/ ENS.
LARGE ENSEMBLE
S/GR.
S/ ENS.
IDF
CORRIDOR
CORRIDOR
VESTIBULE
STO
BAND REHEARSAL CLASSROOM
OFFICE
STORAGE
ATHL STO
INSTRUMENT STOUNIFORM STO.
CLASSROOM
HALL
S/GR. OFFICE
S/GR.OFFICE
S/GR.
M/ PRACTICE
ORCHESTRA REHEARSAL
STOR.
C/E STO.
M/ ENS.
DR/UN STO.
VOCAL
OFFICE
S/GR.
S/GR.
CHORUS REHEARSAL
MUSIC LIB.
VEST
L & D/STO.CONTROL
DRAMA REHEARSAL / PERFORMANCE
SCENE/PROP STORAGE
OFFICE
DRAMA CLASSROOM
C.R. STO.
SHOWERS
TRAIN
STO
COACH OFF
COACH OFFTLT
TLT
JAN
JAN
SHOWERS TOILET
WEST GYM
STORAGE
ASSEMBLY ROOM
SECURITY
ELEV 3
SUB OFF
HOME EC
SE CR
KITCHENETTE
TLT
SE CR
SE CR
SE CR
C134
LOBBY
TLT
STORAGE GYM
CONCESION GYM STO.GYM STO.JAN
TLT TLT
CORRIDOR
CORRIDOR
LOBBY
CLR
CLR
SCI LAB
WORK RM
PREP
LOTE
LOTE
IDF
JAN
ELEC.
GIRL'S TLT
BOY'S TLT
TOILET
CORRIDOR
ART
STO
ART
ESL
LSSP OFF
TLT
ART STO
TLT
KILN RM
STAIR 7
EAST GYM
TLT
TLT
LOUNGE
LAUNDRY
MECH
STAIR
GYM STO
TLT TLT
COST. OFF.
TLT
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
TLT
DRESS
DRESS
AUDITORIUM
CAFETERIA
KITCHEN
PTA SUPPLY RM
STAGE
STAIR 4
PIANO
COSTUME
STO
CORRIDOR
STO
CON
CORRIDOR
CORRIDOR
VEST
STAIR 6
LOBBY
TLT
TLT
CONF.
F/TLTIDF
JAN
VEST
COURTYARD II
COURTYARD I
5/6 GYM
OFF
OFF
STO
STO STO
CR ART STO ART
JAN
ELEC
GIRL'S TLTBOY'S TLT
TLT
CORRIDOR
STO
STAIR 2
SECURITY
VEST
STAIR 3SPED CR
ELECT
IDF
IDF
CORRIDOR
ELECT
CORR
CORR
VEST
ROOM
STAIR 5
BLDG ADDITION
BLDG ADDITION BLDG ADDITIONBLDG ADDITIONNon-
Doc
D1
Non-
DocF1
Non-
Doc
D4
Non-
Doc F4F3
A201
LOBBYELEV
STAIRSTORAGE
PARKING GARAGE
1 2 3 4 5 6 7 8
A
B
C
D
E
F
The Contractor shall verify and be responsible for all dimensions. DO
NOT scale the drawing - any errors or omissions shall be reported to
Stantec without delay.
The Copyrights to all designs and drawings are the property of
Stantec. Reproduction or use for any purpose other than that
authorized by Stantec is forbidden.
Copyright Reserved
Client/Project
Drawing No.
Project No.
Title
ORIGINAL SHEET - ARCH E1 (30"x42")
Permit-Seal
Revision
Revision
Scale
Consultant Type
By Appd YYYY.MM.DD
By Appd YYYY.MM.DDIssued
PRELIMINARY
NOT FOR CONSTRUCTION
Not for permits, pricing or other official purposes.
This document has not been completed or checked and is
for general information or comment only.
Consultants
Key Plan
Notes
Consultant Name
www.stantec.com
3/9/2017 2:48:00 PMC:\Users\Public\Documents\Local_Revit_Files\214000466-MISHPMS-A16_ddain.rvt 1" = 30'-0"
MIS / HPMS Additions and Renovations
Highland Park ISD
OVERALL FIRST FLOOR PLAN &
UNDERGROUND PARKING GARAGE
PD111R
214000466
3555 Granada Ave, Dallas TX 75205
PD RE-SUBMITTAL JC BH 2017.03.10
Stantec Architecture Inc.
5717 Legacy Drive Suite 250
Plano, TX 75024-4246
Tel: (214) 473-2400 / Fax: (214) 473-2401
1" = 30'-0"PD111R
F1 OVERALL FLOOR PLAN - FIRST LEVEL
1" = 30'-0"PD111R
E4 OVERALL FLOOR PLAN - UNDERGROUND PARKING GARAGE
C1
A201
B3A201E4
A201E1A201 B1
A201
C6
A201
F1A201C7
A201
CLRM
LAB
CLRM
LAB
WRKRMLAB PREP
CLRM
CLRM
CLRM
CLRM
WRKRM LAB PREP
ELEC
TLT
ELEV 1
CONF.
GIRLS
BOYS
WK/COPY
IDF
CORR
FLEX SPACE
BOYS
JAN
TLT
GIRLS
ELEV 2
WK/COPY
CLRM
CLRM
WRK
LAB
CLRM
FLEX SPACE
ELEC
LAB PREP
MULTI-MEDIA LAB
CORRIDOR
STOR
JOURNALISM
STORAGE
OFFICE
FILM STUDIO
STOR
CONTROL
BLDG ADDITION
BLDG ADDITION BLDG ADDITIONBLDG ADDITIONSTAIR 1
STAIR 9
STAIR 8
IDF
CR CR MECH CR
STO
JAN
PREP TLT
JAN
ELEC
CR
CR
CR WORK RM CR
LAB
LAB
CRWORK RMCR
LAB
CR WORK RM CR
CR
CR
CRWORK RMCR
LAB
TLT
TLT
PREP
PREP
E
TLT
TLT
HP RAIDER LIRARY
CONFOFF
L & FOFFICECOPY RM
COMP LAB
CONF
WORK RM
OFF
ITOFF
STO
STO
STO
OFF
CR
WORK RM
CR
LAB LAB
CR
CR
CR
WORK RM
CR
E
LAB LAB
CR
WORK RM
CR
CR CR
CR
WORK RM
CR
JAN
SMAL GROUP
TLT TLT
PREP PREP
TLT TLT
SEATING
CONTROL
LOTE
LOTE
LOTE
HEALTH CR
LOTE
LOTE
WORK RM TLT
TLT
STO
MECH
PREP JAN
TOILET
CORRIDOR
GIRL'S BOY'S
CORRIDORTOILET
TLT
STO
STO
CORRIDOR
CORRIDOR
STAIR 5
CORRIDOR
STAIR 7
STAIR 6
STAIR 2
STAIR 3
TLT
TLT
CORRIDOR
CORR
CORR
CORRIDOR
CORRIDOR
CORR
CORR
STAIR 3
CORR
CORR
CORR CORR
CORR
NEW ROOF BELOW
EXISTING
ROOF
EXISTING
ROOF
EXISTING GYM BELOW
EXISTING
ROOF
NEW ROOF BELOW
EXISTING
ROOF
EXISTING
AUDITORIUM
EXISTING
ROOF
EXISTING GYM
BELOW
Non-
Doc
D1
Non-
DocF1
Non-
Doc
D4
Non-
Doc F4F3
A201
1 2 3 4 5 6 7 8
A
B
C
D
E
F
The Contractor shall verify and be responsible for all dimensions. DO
NOT scale the drawing - any errors or omissions shall be reported to
Stantec without delay.
The Copyrights to all designs and drawings are the property of
Stantec. Reproduction or use for any purpose other than that
authorized by Stantec is forbidden.
Copyright Reserved
Client/Project
Drawing No.
Project No.
Title
ORIGINAL SHEET - ARCH E1 (30"x42")
Permit-Seal
Revision
Revision
Scale
Consultant Type
By Appd YYYY.MM.DD
By Appd YYYY.MM.DDIssued
PRELIMINARY
NOT FOR CONSTRUCTION
Not for permits, pricing or other official purposes.
This document has not been completed or checked and is
for general information or comment only.
Consultants
Key Plan
Notes
Consultant Name
www.stantec.com
3/9/2017 2:48:06 PMC:\Users\Public\Documents\Local_Revit_Files\214000466-MISHPMS-A16_ddain.rvt 1" = 30'-0"
MIS / HPMS Additions and Renovations
Highland Park ISD
SECOND LEVEL FLOOR PLAN
PD121R
214000466
3555 Granada Ave, Dallas TX 75205
PD RE-SUBMITTAL JC BH 2017.03.10
Stantec Architecture Inc.
5717 Legacy Drive Suite 250
Plano, TX 75024-4246
Tel: (214) 473-2400 / Fax: (214) 473-2401
1" = 30'-0"PD121R
F2 OVERALL FLOOR PLAN - SECOND LEVEL
C1
A201
B3A201E4
A201E1A201 B1
A201
C6
A201
F1A201C7
A201 B6A201CLRM
CLRM
CLRM
LAB
WRKRM LAB PREP
CLRM
LAB
CLRM
CLRM
WRKRMLAB PREP
CORR
FLEX SPACE
GIRLS
BOYS
IDF
WK/COPY
ELEC
TLT
ELEVATOR 1
CONF.
BOYS
JAN
TLT
GIRLS
ELEVATOR
LAB PREP
WK/COPY
CLRM
CLRM
WRK
LAB
STAIR
CLRM
STAIR 9
FLEX SPACE
ELEC
LAB PREP
CLRM
LAB
WRK
CLRM
CLRM
FLEX SPACE
CORR
STOR
EXISTING
ROOF
EXISTING
ROOF
EXISTING
ROOF
EXISTING
ROOF
EXISTING
ROOF
EXISTING
ROOF
EXISTING
ROOF
EXISTING
ROOF
EXISTING
ROOF
NEW ROOF
STAIR 1
STAIR 9
STAIR 8
IDF
CR
CR
CR
CR
CR CR CREATIVITY RMMECH
STO
JAN
PREP TLT
TLT TLT
TLT
STORAGE
JAN
ELEC
COMP LAB
SPEECH
CR
CR WORK RM CR
LAB
LAB
CRCR
CR
WORK RM
LAB
LAB
CR WORK RM
WORK RMCR
PREP
PREP
TLT
TLT TLT
TLT
ELECT
TLT
STORAGE
IT OFF
COMP LAB
CRCR
CRCR
CRCR
LABLAB
WORK RM WORK RMTLT TLT
STORAGE
STORAGE
LABLAB
CRCR
CR
CR
CRCR
WORK RM WORK RM
SMALL GROUP
PREP PREPE TLT
TLT TLT
BOOK RM
JAN
TLT
STAIR 7
CORRIDOR
CORRIDOR
CORRIDOR
STAIR 3
CORRIDOR
CORRIDOR STAIR
STAIR 5
STAIR 7
STAIR 6
STAIR 2
STAIR 3
CORR
CORRIDOR
CORR
CORR CORR
Non-
Doc
D1
Non-
DocF1
Non-
Doc
D4
Non-
Doc F4F3
A201
1 2 3 4 5 6 7 8
A
B
C
D
E
F
The Contractor shall verify and be responsible for all dimensions. DO
NOT scale the drawing - any errors or omissions shall be reported to
Stantec without delay.
The Copyrights to all designs and drawings are the property of
Stantec. Reproduction or use for any purpose other than that
authorized by Stantec is forbidden.
Copyright Reserved
Client/Project
Drawing No.
Project No.
Title
ORIGINAL SHEET - ARCH E1 (30"x42")
Permit-Seal
Revision
Revision
Scale
Consultant Type
By Appd YYYY.MM.DD
By Appd YYYY.MM.DDIssued
PRELIMINARY
NOT FOR CONSTRUCTION
Not for permits, pricing or other official purposes.
This document has not been completed or checked and is
for general information or comment only.
Consultants
Key Plan
Notes
Consultant Name
www.stantec.com
3/9/2017 2:48:09 PMC:\Users\Public\Documents\Local_Revit_Files\214000466-MISHPMS-A16_ddain.rvt 1" = 30'-0"
MIS / HPMS Additions and Renovations
Highland Park ISD
THIRD LEVEL FLOOR PLAN
PD131R
214000466
3555 Granada Ave, Dallas TX 75205
PD RE-SUBMITTAL JC BH 2017.03.10
Stantec Architecture Inc.
5717 Legacy Drive Suite 250
Plano, TX 75024-4246
Tel: (214) 473-2400 / Fax: (214) 473-2401
1" = 30'-0"PD131R
F2 OVERALL FLOOR PLAN - THIRD LEVEL
1 2 3 4 5 6 7 8
A
B
C
D
E
F
The Contractor shall verify and be responsible for all dimensions. DO
NOT scale the drawing - any errors or omissions shall be reported to
Stantec without delay.
The Copyrights to all designs and drawings are the property of
Stantec. Reproduction or use for any purpose other than that
authorized by Stantec is forbidden.
Copyright Reserved
Client/Project
Drawing No.
Project No.
Title
ORIGINAL SHEET - ARCH E1 (30"x42")
Permit-Seal
Revision
Revision
Scale
Consultant Type
By Appd YYYY.MM.DD
By Appd YYYY.MM.DDIssued
PRELIMINARY
NOT FOR CONSTRUCTION
Not for permits, pricing or other official purposes.
This document has not been completed or checked and is
for general information or comment only.
Consultants
Key Plan
Notes
Consultant Name
www.stantec.com
3/9/2017 2:48:10 PMC:\Users\Public\Documents\Local_Revit_Files\214000466-MISHPMS-A16_ddain.rvt 6" = 1'-0"
MIS / HPMS Additions and Renovations
Highland Park ISD
RENDERINGS
PD200R
214000466
3555 Granada Ave, Dallas TX 75205
PD RE-SUBMITTAL JC BH 2017.03.10
Stantec Architecture Inc.
5717 Legacy Drive Suite 250
Plano, TX 75024-4246
Tel: (214) 473-2400 / Fax: (214) 473-2401
6" = 1'-0"PD200R
C2 NORTH VIEW - BLDG 3 ADDITION
6" = 1'-0"PD200R
F2 WEST VIEW - BLDG 4 ADDITION
FIRST LEVEL
0"
SECOND LEVEL
15' - 4"
THIRD LEVEL
30' - 8"
TOW @ BLDG 3
48' - 8"
EXISTING BUILDINGPROPOSED BUILDING ADDITION48' - 8"BK2 BK1
PEAK AT HIGH ROOF
66' - 10"
CANOPY
CORNER BRICK
PATTERN, TYP.
RECESSED GFRC
PANELS, TYP.
FIRST LEVEL
0"
SECOND LEVEL
15' - 4"
THIRD LEVEL
30' - 8"
TOW @ BLDG 4
46' - 0"
PROPOSED NEW BUILDINGEXISTING BUILDING
BK2
BK1
CANOPY
CORNER BRICK
PATTERN, TYP.
RECESSED GFRC
PANELS, TYP.
FIRST LEVEL
0"
SECOND LEVEL
15' - 4"
THIRD LEVEL
30' - 8"
TOW @ BLDG 3
48' - 8"
PROPOSED BUILDING ADDITION48' - 8"BK2
BK1
CORNER BRICK
PATTERN, TYP.
RECESSED GFRC
PANELS, TYP.
FIRST LEVEL
0"
SECOND LEVEL
15' - 4"
THIRD LEVEL
30' - 8"
TOW @ BLDG 4
46' - 0"46' - 0"TOW @ BAND HALL
30' - 8"
BK2BK2
BK2
BK1 22' - 8"15' - 4"26' - 0"
CORNER BRICK
PATTERN, TYP.
RECESSED GFRC
PANELS, TYP.
FIRST LEVEL
0"30' - 8"TOW @ BAND HALL
30' - 8"
PROPOSED BUILDING ADDITION EXISTING BUILDING
BK1 BK2
CORNER BRICK
PATTERN, TYP.
CANOPY
FIRST LEVEL
0"
SECOND LEVEL
15' - 4"
THIRD LEVEL
30' - 8"
TOW @ BLDG 3
48' - 8"48' - 8"PROPOSED BUILDING ADDITIONEXISTING BUILDING
BK2
BK1
15' - 4"CORNER BRICK
PATTERN, TYP.
FIRST LEVEL
0"
SECOND LEVEL
15' - 4"
THIRD LEVEL
30' - 8"
TOW @ BLDG 4
46' - 0"
BK2
CORNER BRICK
PATTERN, TYP.
FIRST LEVEL
0"
SECOND LEVEL
15' - 4"
THIRD LEVEL
30' - 8"
TOW @ BLDG 4
46' - 0"
BK2
BK1
RECESSED GFRC
PANELS, TYP.
CORNER BRICK
PATTERN, TYP.
FIRST LEVEL
0"
SECOND LEVEL
15' - 4"
THIRD LEVEL
30' - 8"
TOW @ BLDG 4
46' - 0"
BK2
BK1
15' - 4"CORNER BRICK
PATTERN, TYP.
SECOND LEVEL
15' - 4"
THIRD LEVEL
30' - 8"
TOW @ BLDG 3
48' - 8"
GYM FIRST FLOOR
8"
BK2 EXISTING BLDG.
CORNER BRICK
PATTERN, TYP.
FIRST LEVEL
0"
TOW @ BAND HALL
30' - 8"
PROPOSED BLDG ADDITIONEXIST BLDG
BK2 BK2
FIRST LEVEL
0"
SECOND LEVEL
15' - 4"
THIRD LEVEL
30' - 8"
TOW @ BLDG 4
46' - 0"
EXISTING BLDG.
BK2 CORNER BRICK
PATTERN, TYP.
1 2 3 4 5 6 7 8
A
B
C
D
E
F
The Contractor shall verify and be responsible for all dimensions. DO
NOT scale the drawing - any errors or omissions shall be reported to
Stantec without delay.
The Copyrights to all designs and drawings are the property of
Stantec. Reproduction or use for any purpose other than that
authorized by Stantec is forbidden.
Copyright Reserved
Client/Project
Drawing No.
Project No.
Title
ORIGINAL SHEET - ARCH E1 (30"x42")
Permit-Seal
Revision
Revision
Scale
Consultant Type
By Appd YYYY.MM.DD
By Appd YYYY.MM.DDIssued
PRELIMINARY
NOT FOR CONSTRUCTION
Not for permits, pricing or other official purposes.
This document has not been completed or checked and is
for general information or comment only.
Consultants
Key Plan
Notes
Consultant Name
www.stantec.com
3/9/2017 10:15:19 AMC:\Users\Public\Documents\Local_Revit_Files\214000466-MISHPMS-A16_ddain.rvt 1/16" = 1'-0"
MIS / HPMS Additions and Renovations
Highland Park ISD
EXTERIOR ELEVATIONS
214000466
3555 Granada Ave, Dallas TX 75205
PD RE-SUBMITTAL JC DD 2017.03.10
Stantec Architecture Inc.
5717 Legacy Drive Suite 250
Plano, TX 75024-4246
Tel: (214) 473-2400 / Fax: (214) 473-2401
1/16" = 1'-0"A201
C1 NORTH ELEVATION - BLDG 3
1/16" = 1'-0"A201
E1 WEST ELEVATION - BLDG 4
1/16" = 1'-0"A201
B3 EAST ELEVATION - BLDG 3
1/16" = 1'-0"A201
E4 SOUTH ELEVATION - BLDG 4
1/16" = 1'-0"A201
F7 EAST ELEVATION - BLDG 4 / AT BAND HALL
1/16" = 1'-0"A201
B1 SOUTH ELEVATION - BLDG 3
1/16" = 1'-0"A201
C7 NORTH ELEVATION - BLDG 4
1/16" = 1'-0"A201
C6 NORTH ELEVATION - BLDG 4
1/16" = 1'-0"A201
F1 EAST ELEVATION - BLDG 4 / AT CLASSROOMS
1/16" = 1'-0"A201
B6 WEST ELEVATION - BLDG 3
1/16" = 1'-0"A201
F5 WEST ELEVATION BLDG 4 / AT BAND HALL
1/16" = 1'-0"A201
F3 NORTH ELEVATION - BLDG 4 / AT CLASSROOMS
PD201R
1 2 3 4 5 6 7 8
A
B
C
D
E
F
The Contractor shall verify and be responsible for all dimensions. DO
NOT scale the drawing - any errors or omissions shall be reported to
Stantec without delay.
The Copyrights to all designs and drawings are the property of
Stantec. Reproduction or use for any purpose other than that
authorized by Stantec is forbidden.
Copyright Reserved
Client/Project
Drawing No.
Project No.
Title
ORIGINAL SHEET - ARCH E1 (30"x42")
Permit-Seal
Revision
Revision
Scale
Consultant Type
By Appd YYYY.MM.DD
By Appd YYYY.MM.DDIssued
PRELIMINARY
NOT FOR CONSTRUCTION
Not for permits, pricing or other official purposes.
This document has not been completed or checked and is
for general information or comment only.
Consultants
Key Plan
Notes
Consultant Name
www.stantec.com
3/9/2017 8:44:27 PMC:\Users\Public\Documents\Local_Revit_Files\214000466-MISHPMS-A16_ddain.rvt 12" = 1'-0"
MIS / HPMS Additions and Renovations
Highland Park ISD
STREET VIEWS SHOWING RTUS
PD210R
214000466
3555 Granada Ave, Dallas TX 75205
PD RE-SUBMITTAL JC BH 2017.03.10
Stantec Architecture Inc.
5717 Legacy Drive Suite 250
Plano, TX 75024-4246
Tel: (214) 473-2400 / Fax: (214) 473-2401
12" = 1'-0"PD210R
F1 GRANADA STREET EAST VIEW - BLDG 3 ADDITION
12" = 1'-0"PD210R
F4 GRANADA STREET WEST VIEW - BLDG 3 ADDITION
12" = 1'-0"PD210R
D1 HIGH SCHOOL AVENUE NORTH VIEW - BLDG 4 ADDITION
12" = 1'-0"PD210R
D4 HIGH SCHOOL AVENUE SOUTH VIEW - BLDG 4 ADDITION
12" = 1'-0"PD210R
B1 KEY STREET SOUTH VIEW - BLDG 3 ADDITION
12" = 1'-0"PD210R
B4 NORMANDY AVENUE EAST VIEW - BLDG 4 ADDITION
ORDINANCE NO. 17-0 14
AN ORDINANCE OF THE CITY OF UNIVERSITY PARK, TEXAS, AMENDING THE
COMPREHENSIVE ZONING ORDINANCE AND MAP, AS HERETOFORE AMENDED,
BY AMENDING PLANNED DEVELOPMENT DISTRICT NO. 19 FOR THE PROPERTY
DESCRIBED AS LOTS 1-28, BLOCK E, UNIVERSITY ANNEX ADDITION TO THE CITY
OF UNIVERSITY PARK, DALLAS COUNTY, TEXAS, BEING COMMONLY KNOWN AS
3555 GRANADA; APPROVING AN AMENDED DETAILED SITE PLAN; PROVIDING
SPECIAL CONDITIONS; PROVIDING FOR THE REPEAL OF ALL ORDINANCES IN
CONFLICT; PROVIDING A SEVERABILITY CLAUSE; PROVIDING FOR A PENALTY
OF FINE NOT TO EXCEED THE SUM OF TWO THOUSAND DOLLARS ($2,000.00) FOR
EACH OFFENSE; AND PROVIDING AN EFFECTIVE DATE.
DULY PASSED by the City Council of the City of Unive rsity Park, Texas, on the 16th day
of May 201 7.
APPROVED:
MAYOR (/
ATTEST:
/ '
~~.~
CITY SECRETARY