Loading...
HomeMy WebLinkAboutOrdinance 17-014 Amending Planned Development District PD-19 to build two additions to the existing school and siteORDINANCE NO. 17-014 AN ORDINANCE OF THE CITY OF UNIVERSITY PARK, TEXAS, AMENDING THE COMPREHENSIVE ZONING ORDINANCE AND MAP, AS HERETOFORE AMENDED, BY AMENDING PLANNED DEVELOPMENT DISTRICT NO. 19 FOR THE PROPERTY DESCRIDED AS LOTS 1-28, BLOCK E, UNIVERSITY ANNEX ADDITION TO THE CITY OF UNIVERSITY PARK, DALLAS COUNTY, TEXAS, BEING COMMONLY KNOWN AS 3555 GRANADA; APPROVING AN AMENDED DETAILED SITE PLAN; PROVIDING SPECIAL CONDITIONS; PROVIDING FOR THE REPEAL OF ALL ORDINANCES IN CONFLICT; PROVIDING A SEVERABILITY CLAUSE; PROVIDING FOR A PENALTY OF FINE NOT TO EXCEED THE SUM OF TWO THOUSAND DOLLARS ($2,000.00) FOR EACH OFFENSE; AND PROVIDING AN EFFECTIVE DATE. WHEREAS, the Planning and Zoning Commission of the City of University Park and the City Council ofthe City of University Park, in compliance with the laws ofthe State ofTexas with reference to the granting of zoning classifications and changes, have given the requisite notices by publication and otherwise, and have held due hearings and afforded a full and fair hearing to all property owners generally and to all persons interested and situated in the affected area and in the vicinity thereof, and the City Council of the City of University Park is of the opinion and finds that said zoning change should be granted and that the Comprehensive Zoning Ordinance and Map should be amended; NOW, THEREFORE, BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF UNIVERSITY PARK, TEXAS: SECTION 1. That the Comprehensive Zoning Ordinance and Map are amended by amending Planned Development District No. 19 ("PD-19"), for the property described as Lots 1-28, Block E, University Annex Addition to the City of University Park, Dallas County, Texas, commonly known as 3555 Granada Avenue, the Hi ghland Park Middle School and the McCulloch Intermediate School (the "site"), and approving an amended detailed site plan (the "plan "), subject to additional special conditions, for addition of a three story classroom building on the northeast corner ofthe site (Building No. 3), relocation of the tennis court, reconfiguration of parking spaces, and interior renovations. This amendment affects only the portion of the site in the City; the balance of the site is in the Town of Highland Park and the plan will be considered by the Highland Park Town Council in the manner provided by law. SECTION 2. That the amended detailed site plan for PO No. 19, attached hereto, collectively, as Exhibit "A" and made part hereof for all purposes, is hereby approved as the detailed site plan for said Planned Development District 19, as required by Section 17-10 I (2) of the Comprehensive Zoning Ordinance of the City of University Park, Texas. That the Planning and Zoning Commission has reviewed the plan and unanimously recommended its approval. SECTION 3. That the amendment of the plan for PD-19 is subject to the following additional special conditions: a. All pennanent improvements in thi s PD-19 will be constructed or placed and maintained in accordance with the plan; b. HPISD will provide adequate security lighting during construction of the additions shown on the plan approved hereby; c. The construction site will be screened with a 72" screening fence of dark green or black windscreen fabric installed on a chain link frame or of other materials approved by the Director of Community Development; all trash receptacles will be placed within the screened area; d. Construction activities on the site will be conducted Monday through Saturday from 7:00 a.m. to 6:00p.m., unless special permission is granted by the Director of Public Works; e. Background checks will be conducted by the District's contractors for all employees on the site prior to their working on the project, and the results of the checks provided to the District, which will retain a file of such checks; no convicted felon or pedophile will be permitted to work on the project site; f. That Building No.3 shall be set back a distance of38.96' from Granada and 107.28 ' from Key Street. Building No.3 shall not exceed 48.8' in height; g. The District shall provide 64 off-street parking spaces, plus 6 handicap spaces (including I van accessible space) above ground, and shall provide 177 parking spaces, plus 6 handicap spaces (including I van accessible space) below ground for the site; h. Permitted temporary uses shall include: construction management and contract administration trailer and offices; construction equipment and/or materials, containers/trailers/buildings; construction materials staging/lay-down/storage areas. Any portion of the site to be used for the temporary construction uses shall be paved with an all-weather surface (minimum 2" minus/#4 crushed stone. These temporary uses will be permitted for 30 months from the effective date of this ordinance; 1. A full-time point of contact will be provided by HPISD to answer questions and complaints during construction; J. All construction vehicles shall be required to park on-site during construction; k. A full-time point of contact will be provided by HPISD to answer questions and complaints during construction; I. The issuance of a building permit is subject t review and approval of building plans for compliance with applicable city codes and ordinances; and, m. Except as amended hereby, the special conditions ofthe ordinance creating, and those of any ordinance amending, PO 19 shall remain in full force and effect. SECTION 4. All ordinances of the City of University Park in conflict with the provisions of this ordinance are hereby repealed. SECTION 5. Should any sentence, paragraph, subdivision, clause, phrase or section ofthis ordinance be adjudged or held to be unconstitutional, illegal or invalid, the same shall not affect the validity of this ordinance or any part or provision thereof, other than the part so declared to be invalid, illegal or unconstitutional, and shall not affect the validity ofthe Comprehensive Zoning Ordinance and Map. SECTION 6. Any person , firm or corporation violating any of the provisions of this ordinance or the Comprehensive Zoning Ordinance, as amended hereby, shall be deemed guilty of a misdemeanor and, upon conviction in the municipal court of the City of University Park, Texas, shall be punished by a fine not to exceed the sum of two thousand dollars ($2,000.00) for each offense, and each day any such violation shall continue shall be deemed to constitute a separate offense. SECTION 7. This ordinance shall take effect immediately from and after its passage and the publication ofthe caption, as the law and Charter in such cases provide. DULY PASSED by the City Council of the City of University Park, Texas, on the 16th day of May 2017. PPROVEDA~~ CITY ATTORNEY (RLD/05 /11 /17; 86209) APPROVED: OLIN B. LANE, MAYOR ATTEST: CHRISTINE GREEN, CITY SECRETARY ORIGINAL SHEET - ARCH E1 (30"x42") Stantec Project #: Drawing No. Project No. Title Revision Scale Revision By Appd YYYY.MM.DD By Appd YYYY.MM.DDIssued The Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing - any errors or omissions shall be reported to Stantec without delay. The Copyrights to all designs and drawings are the property of Stantec. Reproduction or use for any purpose other than that authorized by Stantec is forbidden. Copyright Reserved Tel: Fax: www.stantec.com PRELIMINARY NOT FOR CONSTRUCTION Not for permits, pricing or other official purposes. This document has not been completed or checked and is for general information or comment only. Seal Block 3/9/2017 2:01:54 PM RevitServer:\\000000000\ENTER_PATH MIS / HPMS Additions and Renovations 3555 Granada Ave, Dallas TX 75205 PD RE-SUBMITTAL 2017.03.10 214000466 COVER PD000R 214000466 Author Approver Stantec Architecture Inc. 5717 Legacy Drive Suite 250 Plano, TX 75024-4246 (214) 473-2400 (214) 473-2401 100% DESIGN DEVELOPMENT 2017.01.27 DRAWING INDEX - PD DOCS NO.DRAWING NAME CIVIL C0.10R SITE PLAN LANDSCAPE LP101R OVERALL LANDSCAPE PLAN LP102R LANDSCAPE PLAN AREA A LP103R LANDSCAPE PLAN AREA B ARCHITECTURE PD000R COVER PD011R ARCHITECTURAL SITE PLAN PD111R OVERALL FIRST FLOOR PLAN & UNDERGROUND PARKING GARAGE PD121R SECOND LEVEL FLOOR PLAN PD131R THIRD LEVEL FLOOR PLAN PD200R RENDERINGS PD201R EXTERIOR ELEVATIONS PD210R STREET VIEWS SHOWING RTUS EXHIBIT A 12345678ABCDEFClient/ProjectDrawing No.Project No.TitleORIGINAL SHEET - ARCH E1 (30"x42")Permit-SealRevisionScalePRELIMINARYNOT FOR CONSTRUCTIONNot for permits, pricing or other official purposes.This document has not been completed or checked and isfor general information or comment only.1/26/2017 3:11:30 PMC:\Users\Public\Documents\Local_Revit_Files\214000466-MISHPMS-A16_jcastellanos.rvt MIS / HPMS Additions and RenovationsHighland Park ISD2140004663555 Granada Ave, Dallas TX 75205RevisionByAppdYYYY.MM.DDByAppdYYYY.MM.DDIssued100% CONTRACT DOCUMENTSAuthorApprover2017.04.12ABCDEFGHJKLThe Contractor shall verify and be responsible for all dimensions. DONOT scale the drawing - any errors or omissions shall be reported toStantec without delay.The Copyrights to all designs and drawings are the property ofStantec. Reproduction or use for any purpose other than thatauthorized by Stantec is forbidden.Copyright ReservedConsultant TypeConsultantsKey PlanConsultant Namewww.stantec.comStantec Architecture Inc.5717 Legacy Drive Suite 250Plano, TX 75024-4246Tel: (214) 473-2400 / Fax: (214) 473-2401C0.101"=40'SITE PLANC0.10 PRELIMINARY PRELIMINARY PRELIMINARY 12' CHAIN-LINKFENCE CHAIN-LINKFENCE 31.3 TOWN OF HIGHLAND PARKCITY OF UNIVERSITY PARK CITY OF UNIVERSITY PARK TOWN OF HIGHLAND PARK XXX.XXFL XXX.XXFL 16.1'6.5'1.42' BRICKWALL 1.08'BRICKWALL BRICKWALL BRICKWALL CROSSWA LK CROSSWALK 21 SPACES46 SPACES 3 SPACES16 SPACES16 SPACES10 SPACES1 SPACE1 SPACE2 SPACESBRICKSIGN RD RD PLAQUE PLAQUE GP GP FP PLAQUE GPGPGP FH CO CO CO CO CO CO 555.73TOP 558.79TOP 561.24TOP 552.76TOP 552.16TOP 556.42TOP 561.66TOP 557.08TOP COOLINGTOWER 10' INLET 10' INLET10'INLET 10'INLET546.56FL 4'INLET&549.44 4'INLET&549.12 5' INLET UGP TRANS-FORMERPAD S S 10" OAK S 6" OAK S 10" OAK S 10" PECAN 12" PECAN WV FH S S 29" OAK29" OAK4" OAK S WD GRANADA AVENUE HIGH SCHOOL AVENUENORMANDY AVENUE KEY STREETBINKLEY AVENUE STINSON FIELD NEW TENNIS COURTS NEW HARD SURFACE PLAY 200 UNDERGROUND PARKING SPOTS NEW GARAGE ENTRY/EXIT DRIVE EXITBLDG # 3 ADDITION BLDG # 4 ADDITION EXISTING BUILDING SHOT PUTHIGH JUMP POLE VAULTGARAGE STAIR EXIT RUNNING TRACK RUNNING TRACK 18 183 10 ENTRYLONG JUMPUNDERGROUND TUNNEL TO BUILDING NEW SIDEWALK NEW SIDEWALK NEW SIDEWALK NEW SIDEWALK NEW SIDEWALK EXISTING SOD STREET VIEW ACROSS SIDEWALK - F4/PD210 STREET VIEW ACROSS SIDEWALK - F1/PD210 STREET VIEW ACROSSSIDEWALK - D4/PD210STREET VIEW ACROSSSIDEWALK- D1/PD210STREET VIEW ACROSSSIDEWALK - B1/PD210STREET VIEW ACROSS SIDEWALK - B4/PD210 NO COURT LIGHTING TO BE PROVIDED CAMERA LOCATION - 5'-6" A.F.F. CAMERA LOCATION - 5'-6" A.F.F. CAMERA LOCATION - 5'-6" A.F.F. CAMERA LOCATION - 5'-6" A.F.F. CAMERA LOCATION - 5'-6" A.F.F. CAMERA LOCATION - 5'-6" A.F.F. RENDERING VIEW - C2/PD200 RENDERING VIEW - F2/PD200 1 2 3 4 5 6 7 8 A B C D E F The Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing - any errors or omissions shall be reported to Stantec without delay. The Copyrights to all designs and drawings are the property of Stantec. Reproduction or use for any purpose other than that authorized by Stantec is forbidden. Copyright Reserved Client/Project Drawing No. Project No. Title ORIGINAL SHEET - ARCH E1 (30"x42") Permit-Seal Revision Revision Scale Consultant Type By Appd YYYY.MM.DD By Appd YYYY.MM.DDIssued PRELIMINARY NOT FOR CONSTRUCTION Not for permits, pricing or other official purposes. This document has not been completed or checked and is for general information or comment only. Consultants Key Plan Notes Consultant Name www.stantec.com 3/9/2017 2:35:15 PMC:\Users\Public\Documents\Local_Revit_Files\214000466-MISHPMS-A16_ddain.rvt 1" = 50'-0" MIS / HPMS Additions and Renovations Highland Park ISD ARCHITECTURAL SITE PLAN PD011R 214000466 3555 Granada Ave, Dallas TX 75205 PD RE-SUBMITTAL JC BH 2017.03.10 Stantec Architecture Inc. 5717 Legacy Drive Suite 250 Plano, TX 75024-4246 Tel: (214) 473-2400 / Fax: (214) 473-2401 1" = 50'-0"PD011R F2 ARCHITECTURAL SITE PLAN DN UP DNDN UP C1 A201 B3A201E4 A201E1A201 F7A201B1 A201 C6 A201 F1A201F5A201GIRLS LAB BOYS WK/COPY IDF CLRM CLRM CLRM WRKRMLAB PREP STORAGE STORAGE LARGE ASSEMBLY ELEC TLT VEST ELEV 1 STAIR 1 CORR FLEX SPACE SPED REC. SPED CR SPED CRSTAFF CONF/MTG TLT CORR SPED WRST SPED CRSPED CR CPY WRKRM TLT CORRARD MTG/CONF TEST/ASSMT TEST/ASSMT ELEC S THRPY/SLP OFF S THRPY/SLP OFF S THRPY/SLP OFF ED DIAG OFF LSSP OFF LSSP OFF CORRIDOR CORRIDOR CORRIDOR SPED OFF ARD MTG/CONF CONF.CNSLR OFF CNSLR OFF CNSLR OFFCNSLR OFF CNSLR OFF CORR SPED OFF TLT TLT CONF.STRG CONF. ISS FILES/RECORDS STORAGECOPY/WORK RM ASSEM/TEST CLST SUPPORT STAFF LIFE SKILLSM/SENS. SKILLS CORRIDOR TEACHER'S LOUNGE VAULT/SAFE BOOKKEEPER TREATMENT TLT STRG SICK RM NURSNG WRKST CLINIC RECP JAN TLT M/ GROUP ENS. STO. STO. BOYS GIRLS ELEV 2 CLRM CLRM WRK LAB CLRM STAIR 9 FLEX SPACE LAB PREP STAIR 8 VEST CORRIDOR SHOWERS BOYS LOCKER RM WEIGHT RM BOYS LOCKER RM CLASSROOM GIRLS LOCKER RM S/GR.S/GR. S/GR. OFFICE OFFICE M/ ENS. S/ ENS. LARGE ENSEMBLE S/GR. S/ ENS. IDF CORRIDOR CORRIDOR VESTIBULE STO BAND REHEARSAL CLASSROOM OFFICE STORAGE ATHL STO INSTRUMENT STOUNIFORM STO. CLASSROOM HALL S/GR. OFFICE S/GR.OFFICE S/GR. M/ PRACTICE ORCHESTRA REHEARSAL STOR. C/E STO. M/ ENS. DR/UN STO. VOCAL OFFICE S/GR. S/GR. CHORUS REHEARSAL MUSIC LIB. VEST L & D/STO.CONTROL DRAMA REHEARSAL / PERFORMANCE SCENE/PROP STORAGE OFFICE DRAMA CLASSROOM C.R. STO. SHOWERS TRAIN STO COACH OFF COACH OFFTLT TLT JAN JAN SHOWERS TOILET WEST GYM STORAGE ASSEMBLY ROOM SECURITY ELEV 3 SUB OFF HOME EC SE CR KITCHENETTE TLT SE CR SE CR SE CR C134 LOBBY TLT STORAGE GYM CONCESION GYM STO.GYM STO.JAN TLT TLT CORRIDOR CORRIDOR LOBBY CLR CLR SCI LAB WORK RM PREP LOTE LOTE IDF JAN ELEC. GIRL'S TLT BOY'S TLT TOILET CORRIDOR ART STO ART ESL LSSP OFF TLT ART STO TLT KILN RM STAIR 7 EAST GYM TLT TLT LOUNGE LAUNDRY MECH STAIR GYM STO TLT TLT COST. OFF. TLT CORRIDOR CORRIDOR CORRIDOR CORRIDOR TLT DRESS DRESS AUDITORIUM CAFETERIA KITCHEN PTA SUPPLY RM STAGE STAIR 4 PIANO COSTUME STO CORRIDOR STO CON CORRIDOR CORRIDOR VEST STAIR 6 LOBBY TLT TLT CONF. F/TLTIDF JAN VEST COURTYARD II COURTYARD I 5/6 GYM OFF OFF STO STO STO CR ART STO ART JAN ELEC GIRL'S TLTBOY'S TLT TLT CORRIDOR STO STAIR 2 SECURITY VEST STAIR 3SPED CR ELECT IDF IDF CORRIDOR ELECT CORR CORR VEST ROOM STAIR 5 BLDG ADDITION BLDG ADDITION BLDG ADDITIONBLDG ADDITIONNon- Doc D1 Non- DocF1 Non- Doc D4 Non- Doc F4F3 A201 LOBBYELEV STAIRSTORAGE PARKING GARAGE 1 2 3 4 5 6 7 8 A B C D E F The Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing - any errors or omissions shall be reported to Stantec without delay. The Copyrights to all designs and drawings are the property of Stantec. Reproduction or use for any purpose other than that authorized by Stantec is forbidden. Copyright Reserved Client/Project Drawing No. Project No. Title ORIGINAL SHEET - ARCH E1 (30"x42") Permit-Seal Revision Revision Scale Consultant Type By Appd YYYY.MM.DD By Appd YYYY.MM.DDIssued PRELIMINARY NOT FOR CONSTRUCTION Not for permits, pricing or other official purposes. This document has not been completed or checked and is for general information or comment only. Consultants Key Plan Notes Consultant Name www.stantec.com 3/9/2017 2:48:00 PMC:\Users\Public\Documents\Local_Revit_Files\214000466-MISHPMS-A16_ddain.rvt 1" = 30'-0" MIS / HPMS Additions and Renovations Highland Park ISD OVERALL FIRST FLOOR PLAN & UNDERGROUND PARKING GARAGE PD111R 214000466 3555 Granada Ave, Dallas TX 75205 PD RE-SUBMITTAL JC BH 2017.03.10 Stantec Architecture Inc. 5717 Legacy Drive Suite 250 Plano, TX 75024-4246 Tel: (214) 473-2400 / Fax: (214) 473-2401 1" = 30'-0"PD111R F1 OVERALL FLOOR PLAN - FIRST LEVEL 1" = 30'-0"PD111R E4 OVERALL FLOOR PLAN - UNDERGROUND PARKING GARAGE C1 A201 B3A201E4 A201E1A201 B1 A201 C6 A201 F1A201C7 A201 CLRM LAB CLRM LAB WRKRMLAB PREP CLRM CLRM CLRM CLRM WRKRM LAB PREP ELEC TLT ELEV 1 CONF. GIRLS BOYS WK/COPY IDF CORR FLEX SPACE BOYS JAN TLT GIRLS ELEV 2 WK/COPY CLRM CLRM WRK LAB CLRM FLEX SPACE ELEC LAB PREP MULTI-MEDIA LAB CORRIDOR STOR JOURNALISM STORAGE OFFICE FILM STUDIO STOR CONTROL BLDG ADDITION BLDG ADDITION BLDG ADDITIONBLDG ADDITIONSTAIR 1 STAIR 9 STAIR 8 IDF CR CR MECH CR STO JAN PREP TLT JAN ELEC CR CR CR WORK RM CR LAB LAB CRWORK RMCR LAB CR WORK RM CR CR CR CRWORK RMCR LAB TLT TLT PREP PREP E TLT TLT HP RAIDER LIRARY CONFOFF L & FOFFICECOPY RM COMP LAB CONF WORK RM OFF ITOFF STO STO STO OFF CR WORK RM CR LAB LAB CR CR CR WORK RM CR E LAB LAB CR WORK RM CR CR CR CR WORK RM CR JAN SMAL GROUP TLT TLT PREP PREP TLT TLT SEATING CONTROL LOTE LOTE LOTE HEALTH CR LOTE LOTE WORK RM TLT TLT STO MECH PREP JAN TOILET CORRIDOR GIRL'S BOY'S CORRIDORTOILET TLT STO STO CORRIDOR CORRIDOR STAIR 5 CORRIDOR STAIR 7 STAIR 6 STAIR 2 STAIR 3 TLT TLT CORRIDOR CORR CORR CORRIDOR CORRIDOR CORR CORR STAIR 3 CORR CORR CORR CORR CORR NEW ROOF BELOW EXISTING ROOF EXISTING ROOF EXISTING GYM BELOW EXISTING ROOF NEW ROOF BELOW EXISTING ROOF EXISTING AUDITORIUM EXISTING ROOF EXISTING GYM BELOW Non- Doc D1 Non- DocF1 Non- Doc D4 Non- Doc F4F3 A201 1 2 3 4 5 6 7 8 A B C D E F The Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing - any errors or omissions shall be reported to Stantec without delay. The Copyrights to all designs and drawings are the property of Stantec. Reproduction or use for any purpose other than that authorized by Stantec is forbidden. Copyright Reserved Client/Project Drawing No. Project No. Title ORIGINAL SHEET - ARCH E1 (30"x42") Permit-Seal Revision Revision Scale Consultant Type By Appd YYYY.MM.DD By Appd YYYY.MM.DDIssued PRELIMINARY NOT FOR CONSTRUCTION Not for permits, pricing or other official purposes. This document has not been completed or checked and is for general information or comment only. Consultants Key Plan Notes Consultant Name www.stantec.com 3/9/2017 2:48:06 PMC:\Users\Public\Documents\Local_Revit_Files\214000466-MISHPMS-A16_ddain.rvt 1" = 30'-0" MIS / HPMS Additions and Renovations Highland Park ISD SECOND LEVEL FLOOR PLAN PD121R 214000466 3555 Granada Ave, Dallas TX 75205 PD RE-SUBMITTAL JC BH 2017.03.10 Stantec Architecture Inc. 5717 Legacy Drive Suite 250 Plano, TX 75024-4246 Tel: (214) 473-2400 / Fax: (214) 473-2401 1" = 30'-0"PD121R F2 OVERALL FLOOR PLAN - SECOND LEVEL C1 A201 B3A201E4 A201E1A201 B1 A201 C6 A201 F1A201C7 A201 B6A201CLRM CLRM CLRM LAB WRKRM LAB PREP CLRM LAB CLRM CLRM WRKRMLAB PREP CORR FLEX SPACE GIRLS BOYS IDF WK/COPY ELEC TLT ELEVATOR 1 CONF. BOYS JAN TLT GIRLS ELEVATOR LAB PREP WK/COPY CLRM CLRM WRK LAB STAIR CLRM STAIR 9 FLEX SPACE ELEC LAB PREP CLRM LAB WRK CLRM CLRM FLEX SPACE CORR STOR EXISTING ROOF EXISTING ROOF EXISTING ROOF EXISTING ROOF EXISTING ROOF EXISTING ROOF EXISTING ROOF EXISTING ROOF EXISTING ROOF NEW ROOF STAIR 1 STAIR 9 STAIR 8 IDF CR CR CR CR CR CR CREATIVITY RMMECH STO JAN PREP TLT TLT TLT TLT STORAGE JAN ELEC COMP LAB SPEECH CR CR WORK RM CR LAB LAB CRCR CR WORK RM LAB LAB CR WORK RM WORK RMCR PREP PREP TLT TLT TLT TLT ELECT TLT STORAGE IT OFF COMP LAB CRCR CRCR CRCR LABLAB WORK RM WORK RMTLT TLT STORAGE STORAGE LABLAB CRCR CR CR CRCR WORK RM WORK RM SMALL GROUP PREP PREPE TLT TLT TLT BOOK RM JAN TLT STAIR 7 CORRIDOR CORRIDOR CORRIDOR STAIR 3 CORRIDOR CORRIDOR STAIR STAIR 5 STAIR 7 STAIR 6 STAIR 2 STAIR 3 CORR CORRIDOR CORR CORR CORR Non- Doc D1 Non- DocF1 Non- Doc D4 Non- Doc F4F3 A201 1 2 3 4 5 6 7 8 A B C D E F The Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing - any errors or omissions shall be reported to Stantec without delay. The Copyrights to all designs and drawings are the property of Stantec. Reproduction or use for any purpose other than that authorized by Stantec is forbidden. Copyright Reserved Client/Project Drawing No. Project No. Title ORIGINAL SHEET - ARCH E1 (30"x42") Permit-Seal Revision Revision Scale Consultant Type By Appd YYYY.MM.DD By Appd YYYY.MM.DDIssued PRELIMINARY NOT FOR CONSTRUCTION Not for permits, pricing or other official purposes. This document has not been completed or checked and is for general information or comment only. Consultants Key Plan Notes Consultant Name www.stantec.com 3/9/2017 2:48:09 PMC:\Users\Public\Documents\Local_Revit_Files\214000466-MISHPMS-A16_ddain.rvt 1" = 30'-0" MIS / HPMS Additions and Renovations Highland Park ISD THIRD LEVEL FLOOR PLAN PD131R 214000466 3555 Granada Ave, Dallas TX 75205 PD RE-SUBMITTAL JC BH 2017.03.10 Stantec Architecture Inc. 5717 Legacy Drive Suite 250 Plano, TX 75024-4246 Tel: (214) 473-2400 / Fax: (214) 473-2401 1" = 30'-0"PD131R F2 OVERALL FLOOR PLAN - THIRD LEVEL 1 2 3 4 5 6 7 8 A B C D E F The Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing - any errors or omissions shall be reported to Stantec without delay. The Copyrights to all designs and drawings are the property of Stantec. Reproduction or use for any purpose other than that authorized by Stantec is forbidden. Copyright Reserved Client/Project Drawing No. Project No. Title ORIGINAL SHEET - ARCH E1 (30"x42") Permit-Seal Revision Revision Scale Consultant Type By Appd YYYY.MM.DD By Appd YYYY.MM.DDIssued PRELIMINARY NOT FOR CONSTRUCTION Not for permits, pricing or other official purposes. This document has not been completed or checked and is for general information or comment only. Consultants Key Plan Notes Consultant Name www.stantec.com 3/9/2017 2:48:10 PMC:\Users\Public\Documents\Local_Revit_Files\214000466-MISHPMS-A16_ddain.rvt 6" = 1'-0" MIS / HPMS Additions and Renovations Highland Park ISD RENDERINGS PD200R 214000466 3555 Granada Ave, Dallas TX 75205 PD RE-SUBMITTAL JC BH 2017.03.10 Stantec Architecture Inc. 5717 Legacy Drive Suite 250 Plano, TX 75024-4246 Tel: (214) 473-2400 / Fax: (214) 473-2401 6" = 1'-0"PD200R C2 NORTH VIEW - BLDG 3 ADDITION 6" = 1'-0"PD200R F2 WEST VIEW - BLDG 4 ADDITION FIRST LEVEL 0" SECOND LEVEL 15' - 4" THIRD LEVEL 30' - 8" TOW @ BLDG 3 48' - 8" EXISTING BUILDINGPROPOSED BUILDING ADDITION48' - 8"BK2 BK1 PEAK AT HIGH ROOF 66' - 10" CANOPY CORNER BRICK PATTERN, TYP. RECESSED GFRC PANELS, TYP. FIRST LEVEL 0" SECOND LEVEL 15' - 4" THIRD LEVEL 30' - 8" TOW @ BLDG 4 46' - 0" PROPOSED NEW BUILDINGEXISTING BUILDING BK2 BK1 CANOPY CORNER BRICK PATTERN, TYP. RECESSED GFRC PANELS, TYP. FIRST LEVEL 0" SECOND LEVEL 15' - 4" THIRD LEVEL 30' - 8" TOW @ BLDG 3 48' - 8" PROPOSED BUILDING ADDITION48' - 8"BK2 BK1 CORNER BRICK PATTERN, TYP. RECESSED GFRC PANELS, TYP. FIRST LEVEL 0" SECOND LEVEL 15' - 4" THIRD LEVEL 30' - 8" TOW @ BLDG 4 46' - 0"46' - 0"TOW @ BAND HALL 30' - 8" BK2BK2 BK2 BK1 22' - 8"15' - 4"26' - 0" CORNER BRICK PATTERN, TYP. RECESSED GFRC PANELS, TYP. FIRST LEVEL 0"30' - 8"TOW @ BAND HALL 30' - 8" PROPOSED BUILDING ADDITION EXISTING BUILDING BK1 BK2 CORNER BRICK PATTERN, TYP. CANOPY FIRST LEVEL 0" SECOND LEVEL 15' - 4" THIRD LEVEL 30' - 8" TOW @ BLDG 3 48' - 8"48' - 8"PROPOSED BUILDING ADDITIONEXISTING BUILDING BK2 BK1 15' - 4"CORNER BRICK PATTERN, TYP. FIRST LEVEL 0" SECOND LEVEL 15' - 4" THIRD LEVEL 30' - 8" TOW @ BLDG 4 46' - 0" BK2 CORNER BRICK PATTERN, TYP. FIRST LEVEL 0" SECOND LEVEL 15' - 4" THIRD LEVEL 30' - 8" TOW @ BLDG 4 46' - 0" BK2 BK1 RECESSED GFRC PANELS, TYP. CORNER BRICK PATTERN, TYP. FIRST LEVEL 0" SECOND LEVEL 15' - 4" THIRD LEVEL 30' - 8" TOW @ BLDG 4 46' - 0" BK2 BK1 15' - 4"CORNER BRICK PATTERN, TYP. SECOND LEVEL 15' - 4" THIRD LEVEL 30' - 8" TOW @ BLDG 3 48' - 8" GYM FIRST FLOOR 8" BK2 EXISTING BLDG. CORNER BRICK PATTERN, TYP. FIRST LEVEL 0" TOW @ BAND HALL 30' - 8" PROPOSED BLDG ADDITIONEXIST BLDG BK2 BK2 FIRST LEVEL 0" SECOND LEVEL 15' - 4" THIRD LEVEL 30' - 8" TOW @ BLDG 4 46' - 0" EXISTING BLDG. BK2 CORNER BRICK PATTERN, TYP. 1 2 3 4 5 6 7 8 A B C D E F The Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing - any errors or omissions shall be reported to Stantec without delay. The Copyrights to all designs and drawings are the property of Stantec. Reproduction or use for any purpose other than that authorized by Stantec is forbidden. Copyright Reserved Client/Project Drawing No. Project No. Title ORIGINAL SHEET - ARCH E1 (30"x42") Permit-Seal Revision Revision Scale Consultant Type By Appd YYYY.MM.DD By Appd YYYY.MM.DDIssued PRELIMINARY NOT FOR CONSTRUCTION Not for permits, pricing or other official purposes. This document has not been completed or checked and is for general information or comment only. Consultants Key Plan Notes Consultant Name www.stantec.com 3/9/2017 10:15:19 AMC:\Users\Public\Documents\Local_Revit_Files\214000466-MISHPMS-A16_ddain.rvt 1/16" = 1'-0" MIS / HPMS Additions and Renovations Highland Park ISD EXTERIOR ELEVATIONS 214000466 3555 Granada Ave, Dallas TX 75205 PD RE-SUBMITTAL JC DD 2017.03.10 Stantec Architecture Inc. 5717 Legacy Drive Suite 250 Plano, TX 75024-4246 Tel: (214) 473-2400 / Fax: (214) 473-2401 1/16" = 1'-0"A201 C1 NORTH ELEVATION - BLDG 3 1/16" = 1'-0"A201 E1 WEST ELEVATION - BLDG 4 1/16" = 1'-0"A201 B3 EAST ELEVATION - BLDG 3 1/16" = 1'-0"A201 E4 SOUTH ELEVATION - BLDG 4 1/16" = 1'-0"A201 F7 EAST ELEVATION - BLDG 4 / AT BAND HALL 1/16" = 1'-0"A201 B1 SOUTH ELEVATION - BLDG 3 1/16" = 1'-0"A201 C7 NORTH ELEVATION - BLDG 4 1/16" = 1'-0"A201 C6 NORTH ELEVATION - BLDG 4 1/16" = 1'-0"A201 F1 EAST ELEVATION - BLDG 4 / AT CLASSROOMS 1/16" = 1'-0"A201 B6 WEST ELEVATION - BLDG 3 1/16" = 1'-0"A201 F5 WEST ELEVATION BLDG 4 / AT BAND HALL 1/16" = 1'-0"A201 F3 NORTH ELEVATION - BLDG 4 / AT CLASSROOMS PD201R 1 2 3 4 5 6 7 8 A B C D E F The Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing - any errors or omissions shall be reported to Stantec without delay. The Copyrights to all designs and drawings are the property of Stantec. Reproduction or use for any purpose other than that authorized by Stantec is forbidden. Copyright Reserved Client/Project Drawing No. Project No. Title ORIGINAL SHEET - ARCH E1 (30"x42") Permit-Seal Revision Revision Scale Consultant Type By Appd YYYY.MM.DD By Appd YYYY.MM.DDIssued PRELIMINARY NOT FOR CONSTRUCTION Not for permits, pricing or other official purposes. This document has not been completed or checked and is for general information or comment only. Consultants Key Plan Notes Consultant Name www.stantec.com 3/9/2017 8:44:27 PMC:\Users\Public\Documents\Local_Revit_Files\214000466-MISHPMS-A16_ddain.rvt 12" = 1'-0" MIS / HPMS Additions and Renovations Highland Park ISD STREET VIEWS SHOWING RTUS PD210R 214000466 3555 Granada Ave, Dallas TX 75205 PD RE-SUBMITTAL JC BH 2017.03.10 Stantec Architecture Inc. 5717 Legacy Drive Suite 250 Plano, TX 75024-4246 Tel: (214) 473-2400 / Fax: (214) 473-2401 12" = 1'-0"PD210R F1 GRANADA STREET EAST VIEW - BLDG 3 ADDITION 12" = 1'-0"PD210R F4 GRANADA STREET WEST VIEW - BLDG 3 ADDITION 12" = 1'-0"PD210R D1 HIGH SCHOOL AVENUE NORTH VIEW - BLDG 4 ADDITION 12" = 1'-0"PD210R D4 HIGH SCHOOL AVENUE SOUTH VIEW - BLDG 4 ADDITION 12" = 1'-0"PD210R B1 KEY STREET SOUTH VIEW - BLDG 3 ADDITION 12" = 1'-0"PD210R B4 NORMANDY AVENUE EAST VIEW - BLDG 4 ADDITION ORDINANCE NO. 17-0 14 AN ORDINANCE OF THE CITY OF UNIVERSITY PARK, TEXAS, AMENDING THE COMPREHENSIVE ZONING ORDINANCE AND MAP, AS HERETOFORE AMENDED, BY AMENDING PLANNED DEVELOPMENT DISTRICT NO. 19 FOR THE PROPERTY DESCRIBED AS LOTS 1-28, BLOCK E, UNIVERSITY ANNEX ADDITION TO THE CITY OF UNIVERSITY PARK, DALLAS COUNTY, TEXAS, BEING COMMONLY KNOWN AS 3555 GRANADA; APPROVING AN AMENDED DETAILED SITE PLAN; PROVIDING SPECIAL CONDITIONS; PROVIDING FOR THE REPEAL OF ALL ORDINANCES IN CONFLICT; PROVIDING A SEVERABILITY CLAUSE; PROVIDING FOR A PENALTY OF FINE NOT TO EXCEED THE SUM OF TWO THOUSAND DOLLARS ($2,000.00) FOR EACH OFFENSE; AND PROVIDING AN EFFECTIVE DATE. DULY PASSED by the City Council of the City of Unive rsity Park, Texas, on the 16th day of May 201 7. APPROVED: MAYOR (/ ATTEST: / ' ~~.~ CITY SECRETARY