Loading...
HomeMy WebLinkAboutOrdinance No. 19-001 PD 17 Amendment - Construction of HPISD Science Classroom BuildingORDINANCE NO. 19-001 AN ORDINANCE OF THE CITY OF UNIVERSITY PARK, TEXAS, AMENDING THE COMPREHENSIVE ZONING ORDINANCE AND MAP, AS HERETOFORE AMENDED, BY APPROVING AN AMENDED DETAILED SITE PLAN TO PERMIT CONSTRUCTION OF A NEW SCIENCE CLASSROOM BUILDING AND STUDENT ENTRY IN PLANNED DEVELOPMENT DISTRICT NO. 17 (PD-17), COMMONLY KNOWN AS 4220 EMERSON AVENUE; PROVIDING SPECIAL CONDITIONS; PROVIDING FOR THE REPEAL OF ALL ORDINANCES IN CONFLICT; PROVIDING A SEVERABILITY CLAUSE; PROVIDING FOR A PENALTY OF FINE NOT TO EXCEED THE SUM OF TWO THOUSAND DOLLARS ($2,000.00) FOR EACH OFFENSE; AND PROVIDING AN EFFECTIVE DATE. WHEREAS, the Planning and Zoning Commission of the City of University Park and the City Council of the City of University Park, in compliance with the laws of the State of Texas with reference to the granting of zoning classifications and changes, have given the requisite notices by publication and otherwise, and have held due hearings and afforded a full and fair hearing to all property owners generally and to all persons interested and situated in the affected area and in the vicinity thereof, and the City Council of the City of University Park is of the opinion and finds that said zoning change should be granted and that the Comprehensive Zoning Ordinance and Map should be amended; NOW, THEREFORE, BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF UNIVERSITY PARK, TEXAS: SECTION 1. That the Comprehensive Zoning Ordinance and Map are amended by approval of an amended Detailed Site Plan ("site plan") for Planned Development District No. 17, Highland Park Independent School District ("HPISD"), for the main building of Highland Park High School, 4220 Emerson Avenue, more particularly described as Lot 1A, Block 1, of the Oxford Manor Addition, an Addition to the City of University Park, Dallas County, Texas. SECTION 2. That the site plan is attached hereto in multiple pages cumulatively marked as Exhibit "A" and made part hereof for all purposes is hereby approved as the amended detailed site plan for said portion of PD-17, as required by the Comprehensive Zoning Ordinance of the City of University Park, Texas. That the Planning and Zoning Commission has reviewed and recommended approval of the site plan. SECTION 3. That the amendment of the site plan of PD-17 is subject to the following special conditions: a. All permanent improvements in this portion of Planned Development District No. 17 will be constructed and maintained in accordance with the site plan attached hereto as Exhibit b. The building façade will match the materials, scale and proportion of the other buildings on the campus; c. The existing natatorium and student entry will be demolished and a new three-story Science Classroom Building having a basement and three above grade stories, 10,500 square feet in area each floor (total of 42,000 square feet) and Student Entry constructed abutting Westchester Drive; other renovations will be made to the interior of the building as shown in the site plan; d. The existing parking spaces abutting the subject site will be maintained in accordance with the site plan and no parking is required; e. The height of the new Science Classroom Building will not exceed 54.5'; f. The new Science Classroom Building will be set back 15.25' from the east property line (Westchester Drive) and the new Student Entry will be set back 16.77' from the east property line; and, g. That except as amended hereby, the special conditions of the ordinance creating, and those of any ordinance amending, PD 17 shall remain in full force and effect. SECTION 4. All ordinances of the City of University Park in conflict with the provisions of this ordinance are hereby repealed. SECTION 5. Should any sentence, paragraph, subdivision, clause, phrase or section of this ordinance be adjudged or held to be unconstitutional, illegal or invalid, the same shall not affect the validity of this ordinance or any part or provision thereof, other than the part so declared to be invalid, illegal or unconstitutional, and shall not affect the validity of the Comprehensive Zoning Ordinance and Map. SECTION 6. Any person, firm or corporation violating any of the provisions of this ordinance or the Comprehensive Zoning Ordinance, as amended hereby, shall be deemed guilty of a misdemeanor and, upon conviction in the municipal court of the City of University Park, Texas, shall be punished by a fine not to exceed the sum of two thousand dollars ($2,000.00) for each offense, and every day any such violation shall continue shall be deemed to constitute a separate offense. SECTION 7. This ordinance shall take effect immediately from and after its passage and the publication of the caption, as the law and Charter in such cases provide. DULY PASSED by the City Council of the City of University Park, Texas, on the 15th day of January 2019. APPROVED: OLIN LANE JR, MAYOR APPRO D AS 0 FORM: ATTEST: CITY ATTORNEY CHRISTINE GREEN, CITY SECRETARY (rld/1 1-13-18/104272) ORDINANCE NO. 11 ° ° AN ORDINANCE OF THE CITY OF UNIVERSITY PARK, TEXAS, AMENDING THE COMPREHENSIVE ZONING ORDINANCE AND MAP, AS HERETOFORE AMENDED, BY APPROVING AN AMENDED DETAILED SITE PLAN TO PERMIT CONSTRUCTION OF A NEW SCIENCE CLASSROOM BUILDING AND STUDENT ENTRY IN PLANNED DEVELOPMENT DISTRICT NO. 17 (PD-17), COMMONLY KNOWN AS 4220 EMERSON AVENUE; PROVIDING SPECIAL CONDITIONS; PROVIDING FOR THE REPEAL OF ALL ORDINANCES IN CONFLICT; PROVIDING A SEVERABILITY CLAUSE; PROVIDING FOR A PENALTY OF FINE NOT TO EXCEED THE SUM OF TWO THOUSAND DOLLARS ($2,000.00) FOR EACH OFFENSE; AND PROVIDING AN EFFECTIVE DATE. DULY PASSED by the City Council of the City of University Park, Texas, on the 15th day of January 2019. APPROVED: MAYOR ATTEST: CITY SECRETARY 12345678ABCDEFThe Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing - any errors or omissions shall be reported to Stantec without delay.The Copyrights to all designs and drawings are the property of Stantec. Reproduction or use for any purpose other than that authorized by Stantec is forbidden.Copyright ReservedClient/ProjectDrawing No.Project No.TitleORIGINAL SHEET - ARCH E1 (30"x42")Permit-SealRevisionSheetofRevisionScaleBy Appd YYYY.MM.DDBy Appd YYYY.MM.DDIssuedEXHIBITS FOR ZONING CASE PZ 18-011CHAD McCARTY MARTIN, AIAThis document is submitted for planing and zoning purposes only.LegendNoteswww.stantec.comPLANNING AND ZONING SUBMITTAL 11/1/2018 4:55:14 PMC:\Users\Public\Documents\Local_Revit_Files\stn_ARCH_214000475_02_HPHS II A_R_A18_jmeneses.rvtHighland Park High School Additions &Renovations PHASE 2Highland Park ISDRENDERINGSPD-A200214000475.024220 Emerson AveUniversity Park, TX 752059995% Construction Documents AuthorApprover 2018.10.19Stantec Architecture Inc.5717 Legacy Drive Suite 250Plano, TX 75024-4246Tel: (214) 473-2400 / Fax: (214) 473-2401SCIENCE ADDITION - AREA A -VIEW FROM WESTCHESTER DRIVESTUDENT/EVENT ENTRY ADDITION - AREA F -VIEW FROM WESTCHESTER DRIVESTUDENT/EVENT ENTRY ADDITION - AREA F -VIEW FROM WESTCHESTER DRIVE LEVEL 1 100-0100' - 0"X-2ND L113' - 4 3/4"X- NEW THIRD FLOOR128' - 4 3/4"SCOPE OF NEW WORK147' - 4"130' - 4 1/16"TOP OF ADJACENT PARAPETTOP OF ADJACENT PARAPETTOP OF NEW PARAPETBK1CSMC1CSTOP OF PHASE 1 PARAPET (BEYOND)147' - 4 3/4"146' - 10 11/32"TOP OF EXISTING FLY LOFT (BEYOND)149' - 10"TOP OF EXISTING ROOF LINE (BEYOND)PS1HIGH-LOW WALLS FACING EXISTING ROOFSPS1HIGH-LOW WALLS FACING EXISTING ROOFSa2AD111LEVEL 1 100-0100' - 0"N-LEVEL 3128' - 4 3/4"L2 - AREA G113' - 11 1/2"X- NEW THIRD FLOOR128' - 4 3/4"SCOPE OF NEW WORK139' - 11 1/4"134' - 0"132' - 4 13/16"TOP OF ROOF EDGE- CLERESTORY (AT NEW INFO COMMONS- 120 FEET AWAY FROM BUILDING FACADE)TOP OF ADJACENT PARAPETTOP OF NEW PARAPETTOP OF ADJACENT EXISTING PARAPETBK1CSMC1PS1CSCSPHASE 1 CONSTRUCTION BEYOND147' - 4 3/4"BK1MC1PS1CSMATERIAL LEGENDMASONRY - BRICK 1 (MATCH EXISTING)MORTAR - M1 (MATCH TO EXISTING)CAST STONE (MATCH TO EXISTING)METAL COPING (MATCH TO EXISTING COLOR)PLASTER (MATCH EXISTING PLASTER AND EIFS SURFACES)12345678ABCDEFThe Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing - any errors or omissions shall be reported to Stantec without delay.The Copyrights to all designs and drawings are the property of Stantec. Reproduction or use for any purpose other than that authorized by Stantec is forbidden.Copyright ReservedClient/ProjectDrawing No.Project No.TitleORIGINAL SHEET - ARCH E1 (30"x42")Permit-SealRevisionSheetofRevisionScaleByAppdYYYY.MM.DDBy Appd YYYY.MM.DDIssuedEXHIBITS FOR ZONING CASE PZ 18-011CHAD McCARTY MARTIN, AIAThis document is submitted for planing and zoning purposes only.LegendNoteswww.stantec.comPLANNING AND ZONING SUBMITTAL 11/1/2018 5:07:37 PMC:\Users\Public\Documents\Local_Revit_Files\stn_ARCH_214000475_02_HPHS II A_R_A18_jmeneses.rvt 1/8" = 1'-0"Highland Park High School Additions &Renovations PHASE 2Highland Park ISDEXTERIOR ELEVATIONSPD-A201214000475.024220 Emerson AveUniversity Park, TX 752059995% Construction DocumentsAuthorApprover2018.10.19Stantec Architecture Inc.5717 Legacy Drive Suite 250Plano, TX 75024-4246Tel: (214) 473-2400 / Fax: (214) 473-2401 1/8" = 1'-0"PD-A2011EXTERIOR ELEVATION - SCIENCE ADDITION 1/8" = 1'-0"PD-A2012EXTERIOR ELEVATION - STUDENT/EVENT ENTRYPD-A2013ISOMETRIC OF EAST ELEVATION - FACING WESTCHESTER DRIVE 15' UTILITY EASEMENT L O T 1 D KEKE102 81027555.76555.89RAISED PLANTER(TYPICAL)WOOD SIGN(TYPICAL)WOOD SIGN(TYPICAL)SCOREBOARD RAMPRAMPR A M P RAMPRAMPRAMPGR PVC PIPE M VAULTSIDELINE WATERVAULTLOT 1 L O T 2 8 BLOCK 10 EMERSON CONDOMINIUMS ADDITION (RECORDING INFORMATION NOT FOUND) 2" CHANNEL DRAIN559.59TOP558.39FL2" CHANNEL DRAIN559.26TOP557.62FL554.54TOP G WROUGHT IRONFENCE L548.07F 555.30TOP 556.37TOP 541.67FL BM#1ELEVATION=555.22' BM#2 ELEVATION=555.92' TICKETBOOTHTICKETBOOTH L O T 2 8 DNDNDNDNDNDNDNDNDNUPUPUPUPUPUPUPUPUPUPUPUPUPUPEMERSON DRIVEDOUGLAS AVEWESTCHESTER DRSTUDENT ENTRY BUILDING ADDITIONEXISTING BUILDINGRENDERING VIEWSCIENCE BUILDING ADDITIONRENDERING VIEWRENDERING VIEW NORTHWEST BUILDING ADDITIONPHASE 1INTERIORRENOVATIONINTERIORRENOVATIONNABCDEFGHJ12345678ABCDEFThe Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing - any errors or omissions shall be reported to Stantec without delay.The Copyrights to all designs and drawings are the property of Stantec. Reproduction or use for any purpose other than that authorized by Stantec is forbidden.Copyright ReservedClient/ProjectDrawing No.Project No.TitleORIGINAL SHEET - ARCH E1 (30"x42")Permit-SealRevisionSheetofRevisionScaleByAppdYYYY.MM.DDBy Appd YYYY.MM.DDIssuedEXHIBITS FOR ZONING CASE PZ 18-011CHAD McCARTY MARTIN, AIAThis document is submitted for planing and zoning purposes only.LegendNoteswww.stantec.comPLANNING AND ZONING SUBMITTAL 11/1/2018 4:54:08 PMC:\Users\Public\Documents\Local_Revit_Files\stn_ARCH_214000475_02_HPHS II A_R_A18_jmeneses.rvt 1" = 30'-0"Highland Park High School Additions &Renovations PHASE 2Highland Park ISDARCHITECTURAL SITE PLANPD-A001214000475.024220 Emerson AveUniversity Park, TX 752059995% Construction DocumentsAuthorApprover2018.10.19Stantec Architecture Inc.5717 Legacy Drive Suite 250Plano, TX 75024-4246Tel: (214) 473-2400 / Fax: (214) 473-2401 1" = 30'-0"PD-A001F2ARCHITECTURAL SITE PLAN UPUPUPUPFLMFLMUPUPUPUPUPSTOBOILERHALLLOCKER RMMECHANICAL RMHUBCLOSETCLOSETSTORAGECORRSTOREQUIPELECSTORCLOSETSTORSTORSTORSEWAGE EJECTORSTORLOCKER ROOMSTORSTORLOCKERSSTORSTORSTORSTORSTORWRESTLING ROOMSTAIRCLOSETMECH RMCLOSETCOLOR LEGENDAcademicAcademic SupportMEP / DataToilet RoomsPrimary Circulation(none)Existing -no work scheduledDIGITAL INTERACTIVE MEDIADIGITAL INTERACTIVE MEDIAMEDIA OFFICEGRAPHIC PRODUCTION WORK ROOMMULTIMEDIA VIDEO EDITING / DIGITALSTUDIOA/V RECORDING STUDIOSTUDIO STCONTROL ROOMVESTSOUND BOOTHDIMMERIDF RMTOILETTOILET TOILET?PHOTOGRAPHY LABDARK ROOMDIM ROOMCHEMICAL STORAGESTORCAMERA STORAGESTORWORK OUT SPACEFUTURE EXPANSIONWORK RMMEETING/FILM RMFUTURE EXPANSIONSTORAGESTORAGESOCCERCROSS COUNTRYGYMNASTICSMECH RMBOYS RR/SHOWERCORRIDORSOCCERGOLF GYMNASTICSBOYS COACHGIRLS COACHCORRIDORGYMNASTICSELEC RMGOLFSTAIRCONF.OFFICESTORAGEBREAKOFFICEACTIVE LEARNING ZONEACTIVE LEARNING ZONEACTIVE LEARNING ZONENABCDEFGHJ12345678ABCDEFThe Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing - any errors or omissions shall be reported to Stantec without delay.The Copyrights to all designs and drawings are the property of Stantec. Reproduction or use for any purpose other than that authorized by Stantec is forbidden.Copyright ReservedClient/ProjectDrawing No.Project No.TitleORIGINAL SHEET - ARCH E1 (30"x42")Permit-SealRevisionSheetofRevisionScaleByAppdYYYY.MM.DDBy Appd YYYY.MM.DDIssuedEXHIBITS FOR ZONING CASE PZ 18-011CHAD McCARTY MARTIN, AIAThis document is submitted for planing and zoning purposes only.LegendNoteswww.stantec.comPLANNING AND ZONING SUBMITTAL 11/1/2018 5:20:54 PMC:\Users\Public\Documents\Local_Revit_Files\stn_ARCH_214000475_02_HPHS II A_R_A18_cmmartin.rvt1" = 20'-0"Highland Park High School Additions &Renovations PHASE 2Highland Park ISDBASEMENT LEVEL FLOOR PLANPD-A101214000475.024220 Emerson AveUniversity Park, TX 752059995% Construction DocumentsAuthorApprover 2018.10.19Stantec Architecture Inc.5717 Legacy Drive Suite 250Plano, TX 75024-4246Tel: (214) 473-2400 / Fax: (214) 473-24011" = 20'-0"PD-A101F3OVERALL FLOOR PLAN - BASEMENT DNDNDNDNDNDNDNDNUPDNDNDNDNDNDNUPUPUPDNUPDNUPDNDNDNUPUPDNUPUPUPUPUP1213EQUIPMENT LEGENDELECTRICAL LEGENDPLUMBING LEGEND 1. MILLWORKFACADE 3. HEATEDMERCHANDISER 5. AMBIENTMERCHANDISER 6. SERVINGCOUNTER 8. POINT OF SALE, BYOWNER 9. MILLWORKFACADE 7. CASHIERCOUNTER 2. REFRIGERATEDMERCHANDISER 4. REFRIGERATEDMERCHANDISERSCHEDULES - HPHS PROJECT 1. 120/208 VOLT, 1 PHASE, 11.4 AMPS., EL 18" A.F.F., S.C.O.FOR REFRIGERATED MERCHANDISER. NEMAL14-30P 2. 208 VOLT, 1 PHASE, 28.7 AMPS., EL 18" A.F.F., S.C.O.FOR HEATED MERCHANDISER. NEMA6-30P 3. 120 VOLT, 1 PHASE, 0.52 AMPS., EL 18" A.F.F., D.C.O.FOR AMBIENT MERCHANDISER. NEMA5-15P 4. 120 VOLT, 1 PHASE, 20.0 AMPS (RATED), EL. 48" A.F.F.,D.C.O. FOR GENERAL USE. (DEDICATEDCIRCUITS) 5. 120 VOLT, 1 PHASE, 20.0 AMP, J.BOX, EL. 18", DEDICATEDCIRCUIT, FOR P.O.S. SYSTEM. ELECTRICAL CONTRACTOR TO 6. 1" EMPTY CONDUIT, EL. 18" A.F.F., EXTEND OPEN CONDUITINWALL UP TO A POINT (MINIMUM 6") ABOVE CEILING LINEFOROWNER'S P.O.S. WIRING SYSTEM. USE EASY SWEEP ELLS ATTURNS. ELECTRICAL CONTRACTOR TO MAKE FINAL CONNECTION 1. 3" FLOOR SINK, SET FLUSH WITH FINISHED FLOOR BYPLUMBER TO RECEIVE WASTE FROM FIXTURES. FLOOR SINKTO HAVE 1/2GRATE. 2. INDIRECT WASTE BYPLUMBER. 3. 1/2" C.W. EL. 48", FOR FUTURE EQUIPMENT. PLUMBINGCONTRACTOR TO PROVIDE AND INSTALL IN-LINE VALVEANDCAP FOR FUTUREUSE.MAKE FINAL CONNECTION TO CASHIERCOUNTER.TO CASHIERCOUNTER.building column withfurr-outmerchandisingshelves belowcoun t e r t o p121344456J123456 789CDNUPUPUPUPUPUPUPUPUPLIFE CENTERPLANETARIUMPROJECTOR RMOFF OFF OFFRECEPTIONOFF FILE RMSPEDTLTCONF. RMSTOSTOTLT - MTLT - WCRCRCRELEC.CRCRCR TLT - MSCI LABAEPOFFBOOKROOMDEBATE RMTLT - WSCI LABGIRLS LOCKER STRSARTARTB-2-aB-1B-HALLB-2CORRIDORDRY RMWEST BLEACHERSCOMPETITION GYM EN101TLTJANCOACHSTORHUBAUX TRAININGWEIGHTSGYMSTOREAST BLEACHERS?CRA-2LABCRPREPCRSCIENCE LABPREPSTOSTOSCIENCE LABCRPREPSTOELECBIOLOGY OFFICEOFFOFFOFFOFFOFFRECEPTIONHUB?OFFICEOFFOFFOFFCRCRCRCRCRCRCRSINKTLT - M TLT - WA HALLSPECIAL EDTOTOSPECIAL ED CROFFSCENE SHOPTECH THEATRE RMC-HALLLANGUAGE LABFINE ARTS OFFOFFTICKET RMC-HALL LIGHTINGAUDITORIUM SC105RECEPTIONPLAID RM.AS PP OFFSC102RECEPTIONCOPY RMWORK RMMAILSTOR THEATRE RM STORCONF RMMAIL RMWORK RMTLTTLTDRDRTLTDRESSING RM.ELVSTOCOURT YARDELEC.STOCRSCIENCE LABPREPMECHTLT - MSTOTLTTLTSTOR.ELEC.WOMENWOMENA HALLFLT. TLTIDFPREPSTOSTOSTOAUD. BACKMECHTLT - MTLT - WVESTJANIDF10' - 2"ELEVOPEN TO BELOWOPEN TO BELOWCOLOR LEGENDAcademicAcademic SupportAdministrativeAdministrative SupportAdministrative CirculationFine ArtsFood ServiceFood Service SupportPhysical EducationPhysical Education SupportPhysical EducationCirculationMEP / DataToilet RoomsPrimary Circulation(none)ORCHESTRASTOLARGE ENSEMBLEINSTRUMENT STOROFFOFFUNIFORM RMINS REPPRAC RMPRAC RMPRAC RMPRAC RMMED ENSCORRFLEX SPACEExisting - no work scheduledCLASSROOMCLASSROOMCLASSROOMCLASSROOMCLASSROOMCLASSROOMPODCORRIDORELEC RMGENIUS BARSTAGEBRAIN STORM RMCONCESSIONSCLASSROOMCLASSROOMDANCE STORAGECLASSROOMCOACHES OFFICESTORCLASSROOMGYMNASIUMDANCE CONFERENCEDANCE CORRIDORFACULTY DININGDANCE OFFICELEARNING LABCLINIC RECEPTIONNURSE STATIONTREATMENT AREAFLEX SPACEOFFICECLASSROOMCLASSROOMCLASSROOMFLEX SPACEPODRECEPTIONSM CONFERENCECRISIS COUNSELING PERSONALCOUNSELORCOUNSELORCOUNSELORMD CONFERENCENEW STUDENT COORDREGISTRARCOUNSELORCOUNSELORCOUNSELORLEAD COUNSELORA.L. COUNSELORCRISIS COUNSELORELECTRICALAP RECEPTIONAP OFFICEAP OFFICE AP ADMIN AP ADMINNABCDEFGHJ12345678ABCDEFThe Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing - any errors or omissions shall be reported to Stantec without delay.The Copyrights to all designs and drawings are the property of Stantec. Reproduction or use for any purpose other than that authorized by Stantec is forbidden.Copyright ReservedClient/ProjectDrawing No.Project No.TitleORIGINAL SHEET - ARCH E1 (30"x42")Permit-SealRevisionSheetofRevisionScaleBy Appd YYYY.MM.DDBy Appd YYYY.MM.DDIssuedEXHIBITS FOR ZONING CASE PZ 18-011CHAD McCARTY MARTIN, AIAThis document is submitted for planing and zoning purposes only.LegendNoteswww.stantec.comPLANNING AND ZONING SUBMITTAL 11/1/2018 4:54:38 PMC:\Users\Public\Documents\Local_Revit_Files\stn_ARCH_214000475_02_HPHS II A_R_A18_jmeneses.rvt 1" = 20'-0"Highland Park High School Additions &Renovations PHASE 2Highland Park ISDFIRST LEVEL FLOOR PLANPD-A111214000475.024220 Emerson AveUniversity Park, TX 752059995% Construction Documents AuthorApprover 2018.10.19Stantec Architecture Inc.5717 Legacy Drive Suite 250Plano, TX 75024-4246Tel: (214) 473-2400 / Fax: (214) 473-2401 1" = 20'-0"PD-A111F3OVERALL FLOOR PLAN - FIRST FLOOR DNUPDNUPDNUPDNUPUPUPUPUPCRCRCRCR2B-1PLANETARIUM BELOWENGLISH DEPT. OFFWORK RMTLT TLTMECH.CRCRSS DEPT OFFICETLT - MCRCRECR2B-2aCRCR2B-2aSTOSCIENCE LABPREPSCIENCE LABCRCRCRTLT - WCR CRCR2D-1CRCRCRROBOTICSCRCRCRTLT - WCRCRCRCRCRTLT - MIDFFAC. RRCRLABPREP?SCIENCE LABLABCRCRSCIENCE LAB2D-HALLPREPSCIENCE LABCRMECH.CRELEC.CLASSROOM2A-HALLWORK RMOFFOFFCOMPUTER LABCOMPUTER LABLIBRARYMECH.STAFF DEV.CONF.HALLACAD CRCRMATH DEPT OFFICECOMP LABOFFRECEPCRHUBHUBIDFOFFSTOMECH.OFFSTOIDFELECSTODISTRICT OFFICESPREP STOSTOAUDITORIUM2D-HALLSTO2B-HALL2B-HALL2D-HALLSTOABCFGOPEN TO BELOWOPEN TO BELOWOPEN TO BELOWELEVCOLOR LEGENDAcademicAcademic SupportPhysical Education SupportMEP / DataToilet RoomsPrimary Circulation(none)OPEN TO BELOWCHOIR HALLRECORDINGCHOIR LIBRARYFLEX SPACEFLEX SPACEFLEX SPACECORRIDORFLEX SPACEExisting -no work scheduledLARGE ENSEMBLECAFETERIA C120CORRIDOR2nd FLOOR CENTRAL PLANTIDF2B-3MUSIC THEORYEQUIPPRAC. RMSTOTEACHER STUDIOMED VCL ENSSTOSTAIR ES1CORRELEVBOOTHRoomVESTVESTRoomCORRIDORVESTVESTDISPLAYDISPLAYSTAIR EC2CLASSROOMCLASSROOMACTIVE LEARNING ZONEFLEX LABLAB PREP / STORAGEFLEX LABTOILETIDF RMTOILETTOILETCLASSROOMJANELEC.BOILERCLASSROOMCLASSROOMCORRIDORCLASSROOMCORRIDORCLASSROOMYEARBOOK BUSINESSLEARNING THEATERTOILETTOILETCORRIDORBREAKOUT AREACLASSROOMMEZZANINECATWALKOFFICEOFFICESTAIRYEARBOOK STUDIOYEARBOOK CLASSROOMOFFICEBREAKOUT AREASTAIR WC2BREAKOUT AREABREAKOUT AREASTAIR EC1BREAKOUT AREAIDF RMYEARBOOK OFFICESTORAGELEARNING LABFLEX SPACEACTIVE LEARNING ZONEPODPODACTIVE LEARNING ZONENEWSPAPER CLASSROOMCLASSROOMSTORAGEELECVESTMEZZANINELRG VCL ENSOPEN TO BELOWELECTRICALNABCDEFGHJ12345678ABCDEFThe Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing - any errors or omissions shall be reported to Stantec without delay.The Copyrights to all designs and drawings are the property of Stantec. Reproduction or use for any purpose other than that authorized by Stantec is forbidden.Copyright ReservedClient/ProjectDrawing No.Project No.TitleORIGINAL SHEET - ARCH E1 (30"x42")Permit-SealRevisionSheetofRevisionScaleByAppdYYYY.MM.DDBy Appd YYYY.MM.DDIssuedEXHIBITS FOR ZONING CASE PZ 18-011CHAD McCARTY MARTIN, AIAThis document is submitted for planing and zoning purposes only.LegendNoteswww.stantec.comPLANNING AND ZONING SUBMITTAL 11/1/2018 5:18:24 PMC:\Users\Public\Documents\Local_Revit_Files\stn_ARCH_214000475_02_HPHS II A_R_A18_cmmartin.rvt1" = 20'-0"Highland Park High School Additions &Renovations PHASE 2Highland Park ISDSECOND LEVEL FLOOR PLANPD-A121214000475.024220 Emerson AveUniversity Park, TX 752059995% Construction DocumentsAuthorApprover 2018.10.19Stantec Architecture Inc.5717 Legacy Drive Suite 250Plano, TX 75024-4246Tel: (214) 473-2400 / Fax: (214) 473-24011" = 20'-0"PD-A121F3OVERALL FLOOR PLAN - SECOND FLOOR DNDNDNCLASSROOMCLASSROOMCLASSROOMSTAIR EC2ORGANIC CHEM LABLAB PREP / STORAGEFLEX LAB- CHEMACTIVE LEARNING ZONEELEC RMTOILETTOILETTOILETELEVATORCORRIDORSTAIR EC1ACTIVE LEARNING ZONEPODPODACTIVE LEARNING ZONECOLOR LEGENDAcademicAcademic SupportMEP / DataToilet RoomsPrimary Circulation(none)Existing -no work scheduledFUTURE SHOPSFUTURE CLASSROOMFUTURE SHOPSFUTURE FLEX SPACEFUTURE CLASSROOMFUTURE CLASSROOMNABCDEFGHJ12345678ABCDEFThe Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing - any errors or omissions shall be reported to Stantec without delay.The Copyrights to all designs and drawings are the property of Stantec. Reproduction or use for any purpose other than that authorized by Stantec is forbidden.Copyright ReservedClient/ProjectDrawing No.Project No.TitleORIGINAL SHEET - ARCH E1 (30"x42")Permit-SealRevisionSheetofRevisionScaleByAppdYYYY.MM.DDBy Appd YYYY.MM.DDIssuedEXHIBITS FOR ZONING CASE PZ 18-011CHAD McCARTY MARTIN, AIAThis document is submitted for planing and zoning purposes only.LegendNoteswww.stantec.comPLANNING AND ZONING SUBMITTAL 11/1/2018 5:19:17 PMC:\Users\Public\Documents\Local_Revit_Files\stn_ARCH_214000475_02_HPHS II A_R_A18_cmmartin.rvt1" = 20'-0"Highland Park High School Additions &Renovations PHASE 2Highland Park ISDTHIRD LEVEL FLOOR PLANPD-A131214000475.024220 Emerson AveUniversity Park, TX 752059995% Construction DocumentsAuthorApprover 2018.10.19Stantec Architecture Inc.5717 Legacy Drive Suite 250Plano, TX 75024-4246Tel: (214) 473-2400 / Fax: (214) 473-24011" = 20'-0"PD-A1311OVERALL FLOOR PLAN - THIRD FLOOR