HomeMy WebLinkAboutOrdinance No. 23-002 PD 33 Amendment - Parking Lot Lights at HPHS2 3 4 5 LOVERS LN. HYER ST. GRASSMERE 1 ELECTRICAL EQUIPMENT RACK BB A C C D D PROPERTY LINE (TYP.) PROPERTY LINE (TYP.) 1 6 (TYP.) EXISTING WOOD FENCE EXISTING WOOD FENCE LIGHT POLE BOLT COVER HAND HOLE COVER AND GROUNDING LUG CLAMP GROUNDING CONDUCTOR TO BOLT ASSEMBLY LEVELING NUT BELOW POLE BASE BASE PLATE CHAMFER GRADE TRANSITION TO PVC COATED RMC AT ELBOWS AND THROUGH CONCRETE COUPLING REINFORCED ROUND CONCRETE BASE. 1. 2. NOTE: BASE HEIGHT: 30" ABOVE FINISHED GRADE FOR ALL LUMINAIRES (SITE POLES). BASE HEIGHT SHALL ACCOUNT FOR GRADING AND SOD, WHEN APPLICABLE. SLOPE POLE TOP VERY SLIGHTLY SO WATER DOES NOT POOL AND CAUSE ANCHOR BOLTS CORROSION. SEE NOTE 1 POLE ANCHORS SEE NOTE 2 2' - 0" ROUND 1' - 6 " 3 - 6 " MI N 0 20 40 8040 1" = 40' N SITE PLAN GENERAL NOTES 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. ELECTRICAL CONTRACTOR SHALL VERIFY WITH CONSTRUCTION MANAGER, THAT A SURVEY HAS BEEN CONDUCTED AND ALL UNDERGROUND UTILITIES IDENTIFIED. CALL DIG TESS. UTILITIES SHOWN ON THESE DRAWINGS ARE FOR REFERENCE ONLY. ELECTRICAL CONTRACTOR SHALL COORDINATE EXACT LOCATION OF ALL EXISTING UTILITIES AND ROUTING OF ALL NEW UNDERGROUND UTILITIES WITH RESPECTIVE TRADES (GENERAL, CIVIL, ETC.), PRIOR TO DIGGING. MINIMIZE DIGGING BY SHARING TRENCHES WHENEVER POSSIBLE. COORDINATE ANY DEMOLITION, TEMPORARY, AND PERMANENT (ELECTRICAL AND TELEPHONE) SERVICES TO THE SITE, WITH THE RESPECTIVE LOCAL UTILITY COMPANY REPRESENTATIVES, IN FIELD, PRIOR TO COMMENCEMENT OF WORK. ALL ASSOCIATED COST/FEES BY THE UTILITY COMPANY SHALL BE INCLUDED IN THE BID PRICE. COORDINATE SERVICE SHUT-DOWNS WITH ALL TRADES INVOLVED ON SITE AND OBTAIN WRITTEN AUTHORIZATION FROM OWNER 72 HOURS PRIOR TO ANY ELECTRICAL AND/OR TELEPHONE SHUT-DOWN. AT COMPLETION OF THE PROJECT, ELECTRICAL CONTRACTOR SHALL REMOVE ALL DE-ENERGIZED CONDUCTORS FROM SITE. OUTDOOR SPARE CONDUITS SHALL INCLUDE PULL STRING AND SHALL BE TERMINATED WITH A CAP. ELECTRICAL CONTRACTOR SHALL DIG OUT ENTIRE LENGTH OF TRENCH TO PROPERLY SET DUCT ELEVATIONS. BEFORE DIGGING, CALL DIG TESS. PROVIDE LOCATOR WARNING TAPE FOR ALL UNDERGROUND CONDUITS AND FEEDERS. ALL CONDUIT DEPTHS SHALL BE COORDINATED WITH FINAL GRADES TO ALLOW FOR MINIMUM REQUIRED CONDUIT DEPTH. REFER TO CIVIL DRAWINGS FOR GRADING PLANS. PROVIDE PULL STRINGS AND CAP/LABEL ALL EMPTY CONDUITS COORDINATE POLE BASE LOCATIONS WITH FENCE AND OTHER SITE CONDITIONS. VERIFY AND NOTE AND DISCREPANCIES WITH CIVIL ENGINEER. SITE PLAN KEYNOTES 2. 3. PROVIDE TRAFFIC RATED PULL BOXES FOR ALL POWER CONDUITS SUCH THAT CONDUIT RUNS DO NOT EXCEED 200 FEET IN LENGTH. COORDINATE LOCATIONS WITH OWNER. CONTRACTOR SHALL BORE UNDER EXISTING PAVEMENT. COORDINATE WITH EXISTING UTILITIES. PROVIDE NEW POLE MOUNTED UTILITY TRANSFORMER. PROVIDE PHOTOCELL AND TIME CLOCK FOR LIGHTING CONTROL LOCATED ADJACENT TO ELECTRICAL PANEL. PROVIDE 240V/1PH 100A RACK MOUNTED PANEL. SERVE PANEL TO NEW POLE MOUNTED UTILITY TRANSFORMER. PROVIDE 30" HIGH CONCRETE POLE BASE FOR ALL LIGHT POLES. 4. 5. Project No.Scale Revision Drawing No.Sheet Title Client/Project Client/Project Logo Permit/Seal Issued Revision Notes Consultant Copyright Reserved By Appd YYYY.MM.DD By Appd YYYY.MM.DD Dsgn.Chkd.YYYY.MM.DDDwn. The Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing - any errors or omissions shall be reported to Stantec without delay. The Copyrights to all designs and drawings are the property of Stantec. Reproduction or use for any purpose other than that authorized by Stantec is forbidden. of File Name: ES101 ORIGINAL SHEET - ARCH D \\ u s 0 5 4 2 - p p f s s 0 1 \ s h a r e d _ p r o j e c t s \ 2 1 4 0 0 0 4 7 5 . 0 2 \ 1 3 d e s i g n a n d s u b m i t \ 2 0 d e l i v e r a b l e s \ 1 2 p a r k i n g l o t l i g h t s a d d s e r v \ e s 1 0 1 20 2 2 . 1 0 . 0 6 3 : 1 9 : 0 1 P M Tel: www.stantec.com Stantec 6080 Tennyson Pkwy Suite 200 Plano, TX, 75024 +1.214.473.2400 A B C D 1 2 3 4 5 HIGHLAND PARK ISD HPHS PARKING LOT LIGHTING 4113 LOVERS LN. UNIVERSITY PARK, TEXAS 214000475 02 2022.10.06 Texas Firm Registration No. 13678. EXP. 2022.11.30 N.T.S.B SITE LIGHTING POLE BASE DETAIL 1" = 40' 0"A ELECTRICAL SITE PLAN GO GO SC ES10101 ELECTRICAL SITE PLAN ISSUED FOR PLANNING AND ZONING 2022.10.06 1. 6. 10/06/2022 BB A C C D D EXISTING WOOD FENCE EXISTING WOOD FENCE PROPERTY LINE (TYP.) 0 20 40 8040 1" = 40' N Project No.Scale Revision Drawing No.Sheet Title Client/Project Client/Project Logo Permit/Seal Issued Revision Notes Consultant Copyright Reserved By Appd YYYY.MM.DD By Appd YYYY.MM.DD Dsgn.Chkd.YYYY.MM.DDDwn. The Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing - any errors or omissions shall be reported to Stantec without delay. The Copyrights to all designs and drawings are the property of Stantec. Reproduction or use for any purpose other than that authorized by Stantec is forbidden. of File Name: ES102 ORIGINAL SHEET - ARCH D \\ u s 0 5 4 2 - p p f s s 0 1 \ s h a r e d _ p r o j e c t s \ 2 1 4 0 0 0 4 7 5 . 0 2 \ 1 3 d e s i g n a n d s u b m i t \ 2 0 d e l i v e r a b l e s \ 1 2 p a r k i n g l o t l i g h t s a d d s e r v \ e s 1 0 2 20 2 2 . 1 0 . 0 6 3 : 1 9 : 1 8 P M Tel: www.stantec.com Stantec 6080 Tennyson Pkwy Suite 200 Plano, TX, 75024 +1.214.473.2400 A B C D 1 2 3 4 5 HIGHLAND PARK ISD HPHS PARKING LOT LIGHTING 4113 LOVERS LN. UNIVERSITY PARK, TEXAS 214000475 02 2022.10.06 Texas Firm Registration No. 13678. EXP. 2022.11.30 1" = 40' 0"A ELECTRICAL LIGHTING PLAN - PHOTOMETRICS GENERAL NOTES 1.VALUES INDICATED ARE INITIAL LIGHTING LEVEL IN FOOTCANDLES (FC). GO GO SC ES102 02 ELECTRICAL LIGHTING PLAN - PHOTOMETRICS 2022.10.06ISSUED FOR PLANNING AND ZONING 10/06/2022